AVR 70 2012 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 14

Read Harman Kardon AVR 70 2012 EMC - CB Certificate online

Page 12 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
13 
Clearances and creepage distances 
13.1 
Clearances in accordance with 13.3  
Considered 
 
Creepage distances in accordance with 13.4  
Considered 
13.2 
Determination of working voltage  
Considered 
13.3 
Clearances  
Basic between the mains: min. 
2.0 mm for 322 Vp; Reinforced 
between pri  and sec.: min. 4.0 
mm for 371 Vp 
13.3.1 
General  
 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9 ............. : 
Basic: between the mains 
conductors: min 3.5 mm; between 
metal bottom chassis and  
Standby board : min. 9.0 mm; 
between back chassis and CP304 
on Standby board: min. 9.4 mm; 
between primary and secondary 
conductors on Standby board: 
min. 6.5 mm; between side 
chassis and CP304 on Standby 
board: min. 9.0 mm; between 
primary conductor of mains switch 
board and switch enclosure : 4.3 
mm 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
Non-hazardous secondary 
circuits. 
N/A 
13.3.4 
Measurement of transient voltages  
 
N/A 
13.4 
Creepage distances  
Basic between the mains: min. 
2.5 mm for 220.1 Vrms; 
Reinforced between pri  and 
sec.: min. 5.4 mm for 260.5 
Vrms 
 
Creepage distances greater than table 11 minimum 
values  
Same as Cl. 13.3.2 
13.5 
Printed boards  
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only)  
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4  
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 
N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
Page of 56
Display