AVR 70 2012 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 9

Read Harman Kardon AVR 70 2012 EMC - CB Certificate online

Page 7 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
b) Hazardous live terminals, instructions for wiring   
None 
N/A 
 
c) Instructions for replacing lithium battery  
No lithium battery 
N/A  
 
d) Class I earth connection warning  
 
N/A 
 
e) Instructions for multimedia system connection  
 
N/A 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 
N/A 
 
g) Warning: battery exposure to heat  
 
N/A 
 
h) Warning: protective film on CRT face  
 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
―To disconnect this apparatus 
from the AC mains completely, 
disconnect the power-supply 
cord plug from the AC 
receptacle.
‖ or equivalent (Writ
ten in the instruction manual) 
 
c) Instructions for permanently connected equipment    
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 
N/A 
 
Hazardous radiation 
N/A 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
No ionising radiation 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1:2007
 ................................................................................... : 
 
N/A 
 
Emission limits under fault conditions  ..................... :   
N/A 
 
7 
Heating under normal operating conditions 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table7.1) 
7.1.1 
Temperature rise of accessible parts  
(see appended table7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table7.1) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
 
N/A 
7.1.4 
Temperature rise of windings  
(see appended table7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
(see appended table7.1) 
 
Constructional requirements with regard to the protection against electric 
shock 
Page of 56
Display