Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. : 
U1 = Max. 37.6  mVp                      
U2 = Max. 32.4  mVp
 
 
c) Discharge not exceeding 45 
μC  
< 45 
μC  
 
d) Energy of discharge not exceeding 350 mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
Test conducted 
9.1.2 
No hazardous live shafts of knobs, handles or levers    
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
Top enclosure: max 2 
 18 mm; 
Side enclosure: max. 2 
 20 mm 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
Test conducted 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
Test conducted 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set controls 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
 
N/A 
 
If C is not greater than 0,1 
μF no test needed  
< 0.
1 μF  
N/A 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
Test conducted 
 
b) Test hook of fig. 4 for 10 s (20 N)  
Test conducted 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
Applied 100 N 
9.2 
No hazard after removing a cover by hand  
No removing a cover by hand 
N/A 
 
10 
Insulation requirements 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 
MΩ min. for reinforced 
insulation  ................................................................. : 
100 M
 
10.2 
Humidity treatment 48 h or 120 h  ........................... : 
120 h, 40 
C, 93 %                   
Tropical climate provided 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
Class II 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
(see appended table 10.3) 
 
11 
Fault conditions 
P 
11.1 
No shock hazard under fault condition  
 
11.2 
Heating under fault condition  
(see appended table 11.2) 
 
Flames extinguish within 10 seconds  
 
 
No hazard from softening solder  
 
Page of 56