AVR 70 2012 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 13

Read Harman Kardon AVR 70 2012 EMC - CB Certificate online

Page 11 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Soldered terminations not used  as protective 
mechanism  
 
11.2.1 
Measurement of temperature rises  
(see appended table 11.2) 
11.2.2 
Temperature rise of accessible parts  
(see appended table 11.2) 
11.2.3 
Temperature rise of parts, other than windings and 
printed boards, providing electrical insulation 
(see appended table 11.2) 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
 
N/A 
11.2.5 
Temperature rise of windings  
(see appended table 11.2) 
11.2.6 
Temperature rise of printed boards shall not exceed 
the limits of table 3 by max. 100 K for max. 5 min 
(see appended table 11.2) 
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
 
N/A 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm²  ................ : 
 
N/A 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min  
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
 
N/A 
 
Class I protective earthing maintained  
 
N/A 
11.2.7 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.6 shall not exceed the limits in table 3, 
item e), "Fault conditions". 
(see appended table 11.2) 
 
12 
Mechanical strength 
P 
12.1.1 
Bump test where mass >7 kg  
Approx. 8.3 kg(> 7 kg) 
12.1.2 
Vibration test  
Test conducted 
12.1.3 
Impact hammer test  
Test conducted 
 
Steel ball test  
Test conducted (h = 0.4 m) 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg   Table-Top apparatus 
N/A 
12.1.5 
Thermoplastic enclosures stress relief test  
Test conducted on front panel 
12.2 
Fixing of knobs, push buttons, keys and levers  
 
N/A 
12.3 
Remote controls with hazardous live parts  
No cable connected remote 
control device 
N/A 
12.4 
Drawers (pull test 50 N, 10 s)  
None 
N/A 
12.5 
Antenna coaxial sockets providing isolation  
 
N/A 
12.6 
Telescoping or rod antennas construction  
Not provided 
N/A 
12.6.1 
Telescoping or rod antennas securement  
Not provided 
N/A 
Page of 56
Display