AVR 70 2012 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 11

Read Harman Kardon AVR 70 2012 EMC - CB Certificate online

Page 9 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Reinforced insulation, two layers each of which meet 
10.3  
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
 
N/A 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
Double insulation provided :        
AC wire  
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
PVC wire (UL recognized)         
thickness: 0.44 mm + 0.58 mm 
 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts. 
 
N/A 
8.11 
Detaching of wires  
 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
All mains wires are provided 
with a two pole-connector 
 
Vibration test carried out  ......................................... : 
Yes  
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
None 
N/A 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
None 
N/A 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
All wires are tested with a force 
of 2 N 
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
 
N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
 
8.19.1 
Disconnect device  
An appliance Inlet provided 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 
N/A 
8.19.2 
Mains switch ON indication  
 
N/A 
8.20 
Switch not fitted in the mains cord  
No switch in the mains cord  
N/A 
8.21 
Bridging components comply with clause 14  
C304 
8.22 
Non-separable thin sheet material  
None 
N/A 
 
Electric shock hazard under normal operating conditions 
P 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No exceeding 1000 V a.c. or 
1500 V d.c. 
N/A 
9.1.1.1 
a) Open circuit voltages  
 
Page of 56