Read Harman Kardon AVR 70 2012 EMC - CB Certificate online
Page 9 of 33
Report No.: 077-207362-000
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
Double insulation provided :
AC wire
AC wire
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
PVC wire (UL recognized)
thickness: 0.44 mm + 0.58 mm
thickness: 0.44 mm + 0.58 mm
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
N/A
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
All mains wires are provided
with a two pole-connector
with a two pole-connector
P
Vibration test carried out ......................................... :
Yes
P
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
None
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
None
N/A
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
All wires are tested with a force
of 2 N
of 2 N
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
P
8.19.1
Disconnect device
An appliance Inlet provided
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
No switch in the mains cord
N/A
8.21
Bridging components comply with clause 14
C304
P
8.22
Non-separable thin sheet material
None
N/A
9
Electric shock hazard under normal operating conditions
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No exceeding 1000 V a.c. or
1500 V d.c.
1500 V d.c.
N/A
9.1.1.1
a) Open circuit voltages
P