- Page 11 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
………………………:
due to hot parts or sharp edges
………………………:
Wires safely anchored away
from parts with high
temperature.
from parts with high
temperature.
P
8.16
Only special supply equipment can be used
……......:
……......:
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
8.17
Insulated winding wire without additional interleaved
insulation ……………………………………………..:
insulation ……………………………………………..:
No such winding wire.
N/A
8.18
Endurance test as required by 8.17 ……………….:
N/A
8.19
Disconnection from the mains
See below
N/A
8.19.1
Disconnect device ………………………………......:
Appliance coupler is used
as disconnect devices.
as disconnect devices.
P
All-pole switch or circuit breaker with >3mm contact
separation
………………………………………………:
separation
………………………………………………:
No all-pole switch or circuit
breaker.
breaker.
N/A
8.19.2 Mains
switch
ON indication ………………………...:
Indicator lamp or FL display
lit-on for mains switch ON
indication, but switch is single
pole only.
lit-on for mains switch ON
indication, but switch is single
pole only.
P
8.20
Switch not fitted in the mains cord …………………:
N/A
8.21
Bridging components comply with clause 14 ……..:
C904capacitor, bridging
contact gaps of the mains relay.
Certified component.
See appended table, list of
critical components.
contact gaps of the mains relay.
Certified component.
See appended table, list of
critical components.
P
8.22 Non-separable
thin
sheet material ………………...:
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation ……….:
with clause 13.3.1 for basic insulation ……….:
No voltage exceeding
1000V ac or 1500V dc.
1000V ac or 1500V dc.
N/A
9.1.1.1
a) Open circuit voltages …………………….:
Mains input voltage
> 35 Vac, see below.
> 35 Vac, see below.
⎯
b) Touch current measured from terminal devices
using the network in annex D ………………………:
using the network in annex D ………………………:
(see appended table 9.1.1.1)
P
c) Discharge not exceeding 45 μC ……...:
No part or contact of a
terminal with stored voltages
between 60V - 15 kV.
terminal with stored voltages
between 60V - 15 kV.
N/A