AVR 460 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 15

Read Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate online

 
 
- Page 11 of 44 - 
 
 
 
 
 Report 
No. 
129952 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges 
………………………: 
Wires safely anchored away 
from parts with high 
temperature. 
8.16 
Only special supply equipment can be used 
……......: 
Not supplied by a special 
supply apparatus. 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation ……………………………………………..: 
No such winding wire. 
N/A 
8.18 
Endurance test as required by 8.17 ……………….: 
 
N/A 
8.19 
Disconnection from the mains 
See below 
N/A 
8.19.1 
Disconnect device ………………………………......: 
Appliance coupler is used  
as disconnect devices. 
 
All-pole switch or circuit breaker with >3mm contact 
separation 
………………………………………………: 
No all-pole switch or circuit  
breaker. 
N/A 
8.19.2 Mains 
switch 
ON indication ………………………...: 
Indicator lamp or FL display 
lit-on for mains switch ON  
indication, but switch is single 
pole only. 
8.20 
Switch not fitted in the mains cord …………………: 
 
N/A 
8.21 
Bridging components comply with clause 14 ……..: 
C904capacitor, bridging  
contact gaps of the mains relay.
Certified component. 
See appended table, list of 
critical components. 
8.22 Non-separable 
thin 
sheet material ………………...: 
 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation ……….: 
No voltage exceeding 
1000V ac or 1500V dc.  
N/A 
9.1.1.1 
a) Open circuit voltages …………………….: 
Mains input voltage 
> 35 Vac, see below. 
 
 
b) Touch current measured from terminal devices 
using the network in annex D ………………………: 
(see appended table 9.1.1.1) 
 
c) Discharge not exceeding 45 μC ……...: 
No part or contact of a 
terminal with stored voltages  
between 60V - 15 kV. 
N/A 
Page of 65
Display