Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online
- Page 37 of 42 -
Report No. 98388
Monitored point:
Under fault conditions specified below - continued
Under fault conditions specified below - continued
dT (K)
Limit dT
(K)
*), C814, S-c;
SB-R channel output signal off immediately.
Other output signal normal operated. Input current stabilised at 2,33A.
No component damaged. No hazard. (Tested time: 10 min)
SB-R channel output signal off immediately.
Other output signal normal operated. Input current stabilised at 2,33A.
No component damaged. No hazard. (Tested time: 10 min)
N/A N/A
*), C902, S-c;
Unit shut down immediately. Input current stabilised at 0,03A.
No component damaged. No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,03A.
No component damaged. No hazard. (Tested time: 10 min)
N/A N/A
**), C902, S-c;
Unit shut down immediately. Input current stabilised at 0,02A.
No component damaged. No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,02A.
No component damaged. No hazard. (Tested time: 10 min)
N/A N/A
*), C915, S-c;
F901 opened immediately. Input current stabilised at 0,03A.
D991 damaged. No hazard. (Tested time: 10 min)
F901 opened immediately. Input current stabilised at 0,03A.
D991 damaged. No hazard. (Tested time: 10 min)
N/A N/A
**), C915, S-c;
Unit shut down immediately. Input current stabilised at 0,02A.
No component damaged. No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,02A.
No component damaged. No hazard. (Tested time: 10 min)
N/A N/A
*), D956 (A to C), S-c;
All output signal off immediately. Sub transformer primary winding
heated up to 114K and thermal fuse opened after 7 min.
Dielectric strength test OK. No hazard. (Tested time: 7 min)
All output signal off immediately. Sub transformer primary winding
heated up to 114K and thermal fuse opened after 7 min.
Dielectric strength test OK. No hazard. (Tested time: 7 min)
Sub transf.
114K
Sub transf.
150K
*), D962 (A to C), S-c;
All output signal off immediately. Sub transformer primary winding
heated up to 103K and thermal fuse opened after 7 min.
Dielectric strength test OK. No hazard. (Tested time: 7 min)
All output signal off immediately. Sub transformer primary winding
heated up to 103K and thermal fuse opened after 7 min.
Dielectric strength test OK. No hazard. (Tested time: 7 min)
Sub transf.
103K
Sub transf.
150K
*), C906, S-c;
F/L and output signal off immediately. Sub transformer primary winding
heated up to 111K and thermal fuse opened after 8 min.
Dielectric strength test OK. No hazard. (Tested time: 8 min)
F/L and output signal off immediately. Sub transformer primary winding
heated up to 111K and thermal fuse opened after 8 min.
Dielectric strength test OK. No hazard. (Tested time: 8 min)
Sub transf.
111K
Sub transf.
150K
*), Speaker output (Front-R channel), S-c;
Unit shut down immediately. Input current stabilised at 0,03A.
No component damaged. No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,03A.
No component damaged. No hazard. (Tested time: 10 min)
N/A N/A
*), Fan stalled
(Left side of main
heat-sink
);
Normal operated.
Measured temperature for components;
1) Main transformer primary winding
2) Main transformer core
3) Sub transformer primary winding
4) Sub transformer core
5) PCB near D991
and stabilised. Input current stabilised at 2,54A.
No component damaged. No hazard. (Tested time: 3 hr 50 min)
2) Main transformer core
3) Sub transformer primary winding
4) Sub transformer core
5) PCB near D991
and stabilised. Input current stabilised at 2,54A.
No component damaged. No hazard. (Tested time: 3 hr 50 min)
1) 89,6K
2) 72,7K
3) 69,8K
4) 64,9K
5) 71,5K
2) 72,7K
3) 69,8K
4) 64,9K
5) 71,5K
1) 150K
2) 150K
3) 150K
4) 150K
5) 110K
2) 150K
3) 150K
4) 150K
5) 110K
*) Tested voltage 253V **) Tested voltage 198V
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded