Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online
- Page 34 of 42 -
Report No. 98388
7.2
TABLE: softening temperature of thermoplastics
N/A
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
T softening
(
o
C)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
>100 2
Between parts separated by double or reinforced insulation
>100 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500 No
Between parts separated by double or reinforced insulation
3000 No