AVR 355 (serv.man6) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 40

Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online

 
 
- Page 32 of 42 - 
 
 
 
 
Report No.  98388 
 
Monitored point: 
dT (K) 
198V 50Hz
dT (K) 
253V 50Hz
dT (K) 
198V 60Hz 
dT (K) 
253V 60Hz 
Limit dT (K)
 *) 
E Capacitor, C916 body 
27,4 
39,4 
27,9 
39,6 
85
°C
 
E Capacitor, C909 body 
29,5 
39,2 
30,3 
39,2 
85
°C
 
Sub 
transformer 
core 
34,6 53,9 34,6 48,3 85 
PCB 
near 
Q805 
40,8 60,4 41,0 60,5 95 
TR, 
Q805 
body 
53,3 81,1 53,6 82,1 - 
FAN body (Internal main heat-sink center) 
31,1 
44,0 
31,6 
43,9 
FAN body (Internal main heat-sink side) 
15,5 
20,8 
16,1 
20,8 
E Capacitor, C941 body 
17,7 
24,9 
18,4 
24,9 
85
°C
 
Main 
heat-sink 
43,2 64,5 43,6 65,3 - 
E Capacitor, C129 body 
10,1 
11,6 
11,1 
11,5 
85
°C
 
PCB 
near 
D992 
68,4 80,3 68,7 81,4 95 
D992 
heat-sink 
70,0 81,8 70,2 83,2 - 
PCB 
near 
D991 
60,3 75,5 60,5 75,8 95 
D991 
heat-sink 
79,3 93,5 79,3 93,8 - 
In-let 
body 
21,7 28,8 22,5 28,8 50 
Main 
transformer 
core 
45,1 60,4 45,0 58,2 95 
Main switch button (located on rear 
panel) 
15,2 19,5 15,9 20,1 - 
Stand 
by 
switch 
button 
2,1 2,8 2,1 3,3 50 
Top enclosure above main transformer 
17,6 
23,7 
14,3 
23,3 
40 
Top enclosure above main heat-sink 
17,1 
24,4 
17,1 
28,5 
40 
Front panel (metallic decorative part) 
10,0 15,2 11,7 16,2 40 
 
 
 
 
 
 
*) Temperature rise limits for Singapore is 10K less. 
 
Winding temperature rise  
measurements 
198V50Hz 253V50Hz 198V60Hz 253V60Hz 
 
 
Ambient temperature t1 (
o
C) : 
24,4 
24,4 
24,4 
24,4 
— 
 
Ambient temperature t2 (
o
C) : 
24,0 
24,0 
24,3 
23,0 
— 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT (K)
 *) 
Insulation 
class 
Main trans. Pri. winding (at 1/8Pmax), 198V 50Hz 
1,810 
2,220 
59,1 
95 
Sub trans. Pri. winding (at 1/8Pmax), 198V 50Hz 
1230 
1400 
36,2 
85 
Main trans. Pri. winding (at 1/8Pmax), 253V 50Hz 
1,810 
2,351 
77,8 
95 
Sub trans. Pri. winding (at 1/8Pmax), 253V 50Hz 
1230 
1513 
60,0 
85 
Main trans. Pri. winding (at 1/8Pmax), 198V 60Hz 
1,810 
2,231 
60,3 
95 
Sub trans. Pri. winding (at 1/8Pmax), 198V 60Hz 
1230 
1406 
37,1 
85 
Main trans. Pri. winding (at 1/8Pmax), 253V 60Hz 
1,810 
2,338 
76,9 
95 
Sub trans. Pri. winding (at 1/8Pmax), 253V 60Hz 
1230 
1471 
52,1 
85 
*) Temperature rise limits for Singapore is 10K less. 
 