Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online
- Page 36 of 42 -
Report No. 98388
Monitored point:
Under fault conditions specified below - continued
Under fault conditions specified below - continued
dT (K)
Limit dT
(K)
*), D123 (A to C), S-c;
Normal operated. Input current stabilised at 2,53A.
F111 opened. No hazard. ( Tested time: 10 min)
Normal operated. Input current stabilised at 2,53A.
F111 opened. No hazard. ( Tested time: 10 min)
N/A N/A
*), C129, S-c;
Normal operated. Input current stabilised at 2,44A.
F110, F111 opened. No hazard. (Tested time: 10 min)
Normal operated. Input current stabilised at 2,44A.
F110, F111 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), C941, S-c;
F/L and output signal off immediately.
Input current stabilised at 1,05A.
R104, R105 opened. No hazard. (Tested time: 10 min)
F/L and output signal off immediately.
Input current stabilised at 1,05A.
R104, R105 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), C930, S-c;
All output signal off immediately. Input current stabilised at 1,22A.
R104, R105 opened. No hazard. (Tested time: 20 min)
All output signal off immediately. Input current stabilised at 1,22A.
R104, R105 opened. No hazard. (Tested time: 20 min)
N/A N/A
*), C122, S-c;
Normal operated. Input current stabilised at 2,53A.
R101 opened. No hazard. (Tested time: 10 min)
Normal operated. Input current stabilised at 2,53A.
R101 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), C117, S-c;
Normal operated. Input current stabilised at 2,53A.
No component damaged. No hazard. (Tested time: 20 min)
Normal operated. Input current stabilised at 2,53A.
No component damaged. No hazard. (Tested time: 20 min)
N/A N/A
*), C951, S-c;
Normal operated. Input current stabilised at 2,53A.
R949, R950 opened. No hazard. (Tested time: 10 min)
Normal operated. Input current stabilised at 2,53A.
R949, R950 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), C201, S-c;
Normal operated. Input current stabilised at 2,46A.
F110, F111 opened. No hazard. (Tested time: 10 min)
Normal operated. Input current stabilised at 2,46A.
F110, F111 opened. No hazard. (Tested time: 10 min)
N/A N/A
*), Q805 (C to E), S-c;
Unit shut down immediately. Input current stabilised at 0,03A.
Q805, Q807, Q857 damaged. R817, R811 opened.
No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,03A.
Q805, Q807, Q857 damaged. R817, R811 opened.
No hazard. (Tested time: 10 min)
N/A N/A
*), Q805 (C to B), S-c;
Unit shut down immediately. Input current stabilised at 0,03A.
No component damaged. No hazard. (Tested time; 10 min)
Unit shut down immediately. Input current stabilised at 0,03A.
No component damaged. No hazard. (Tested time; 10 min)
N/A N/A
*), Q807 (C to E), S-c;
Unit shut down immediately. Input current stabilised at 0,03A.
Q805, Q857 damaged. R819 opened.
No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,03A.
Q805, Q857 damaged. R819 opened.
No hazard. (Tested time: 10 min)
N/A N/A
*), Q807 (C to B), S-c;
Unit shut down immediately. Input current stabilised at 0,03A.
No component damaged. No hazard. (Tested time: 10 min)
Unit shut down immediately. Input current stabilised at 0,03A.
No component damaged. No hazard. (Tested time: 10 min)
N/A N/A
*) Tested voltage 253V **) Tested voltage 198V
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection, O-I = Over Loaded
Click on the first or last page to see other AVR 355 (serv.man6) service manuals if exist.