AVR 355 (serv.man6) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 41

Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online

 
 
- Page 33 of 42 - 
 
 
 
 
Report No.  98388 
 
Monitored point: 
dT (K) 
198V 60Hz
dT (K) 
242V 60Hz 
Limit dT (K)
E Capacitor, C916 body 
27,9 
35,9 
85
°C
 
E Capacitor, C909 body 
30,3 
36,5 
85
°C
 
Sub transformer core 
34,6 
43,5 
85 
PCB near Q805 
41,0 
53,5 
95 
TR, Q805 body 
53,6 
71,8 
FAN body (Internal main heatsink center) 
31,6 
39,3 
FAN body (Internal main heatsink side) 
16,1 
19,9 
E Capacitor, C941 body 
18,4 
23,8 
85
°C
 
Main 
heat-sink 
43,6 57,5 - 
E Capacitor, C129 body 
11,1 
12,2 
85
°C
 
PCB near D992 
68,7 
75,5 
95 
D992 
heat-sink 
 
70,2 77,4 - 
PCB near D991 
60,5 
68,1 
95 
D991 
heat-sink 
79,3 86,7 - 
In-let 
body 
22,5 26,7 50 
Main transformer core 
45,0 
54,1 
95 
Main switch button (located on rear panel) 
15,9 
17,9 
Stand by switch button 
2,1 
4,0 
50 
Top enclosure above main transformer 
14,3 
24,4 
40 
Top enclosure above main heat-sink 
17,1 
22,6 
40 
Front panel (metallic decorative part) 
11,7 
14,2 
40 
 
 
 
 
 
 
Winding temperature rise measurements
 198V 
60Hz
242V 60Hz 
 
 
Ambient temperature t1 (
o
C):
 
24,4 
24,4 
— 
 
Ambient temperature t2 (
o
C):
 
24,3 
24,9 
— 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT (K)  Insulation 
class 
Main trans. Pri. winding (at 1/8Pmax), 198V 60Hz 
1,810 
2,231 
60,3 
95 
Sub trans. Pri. winding (at 1/8Pmax), 198V 60Hz 
1230 
1406 
37,1 
85 
Main trans. Pri. winding (at 1/8Pmax), 242V 60Hz 
1,810 
2,311 
71,2 
95 
Sub trans. Pri. winding (at 1/8Pmax), 242V 60Hz 
1230 
1450 
45,8 
85 
 
 
 
 
 
 
 
Page of 58
Display