Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online
- Page 6 of 42 -
Report No. 98388
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. :
Class II
—
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test box
No test box required.
Tested according to
manufactures instructions.
Tested according to
manufactures instructions.
N/A
5 MARKING
Comprehensible and easily discernible
On front and rear side of
the enclosure.
the enclosure.
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / sprit.
P
5.1 Identification,
maker, model .................................... :
Brand: Harman Kardon
Model: AVR 355/230
See copy of marking plate.
Model: AVR 355/230
See copy of marking plate.
P
Class II symbol if applicable
Class II symbol is applied in
according to IEC 60417-5172.
according to IEC 60417-5172.
P
Rated supply voltage and symbol ........................... :
“220V-230V” or “220V”
and AC-symbol (
~
) used.
P
Frequency if safety dependant
“50/60Hz” or “60Hz”
P
Rated current or power consumption ..................... :
400W
P
5.2 Earth
terminal
Class II apparatus.
N/A
Hazardous live terminals
No hazardous live terminals.
The output signal will rise to
40Vp at Pmax, if the speaker
terminal is disconnected,
No hazard.
The output signal will rise to
40Vp at Pmax, if the speaker
terminal is disconnected,
No hazard.
P
Supply output terminals (other than mains)
“W’ and “A” with rated supply
voltage/frequency marked
closed to the socket-outlet;
voltage/frequency marked
closed to the socket-outlet;
SWITCHED (50W, 0.5A MAX)
P
5.3
Use of triangle with exclamation mark
Correct symbol applied:
printed on rear side in connectio
n with CAUTION of
opening. Further; no incorrect us
e of this symbol is found.
printed on rear side in connectio
n with CAUTION of
opening. Further; no incorrect us
e of this symbol is found.
P