Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online
- Page 8 of 42 -
Report No. 98388
7.1.1
Temperature rise of accessible parts
See appended table
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
See appended table
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
See appended table
P
7.1.4
Temperature rise of windings
See appended table
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
See appended table
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150
o
C
Approved components
according to relevant IEC
standards.
according to relevant IEC
standards.
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand”
not possible.
not possible.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials
N/A
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removable by
hand.
hand.
N/A
8.5
Class I equipment
Class II apparatus
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II apparatus
P
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced
insulation complies with
requirements specified in
clause 10 and 13.
insulation complies with
requirements specified in
clause 10 and 13.
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
The apparatus have
isolating transformers
isolating transformers
P