SERVICE MANUAL
SAL300F28G (2.8/300 G) (300mm F2.8 G)
Ver. 1.4  2010.03
Sony EMCS Co.
2010C0800-1
© 2010.03
Published by Tokai TEC
US Model
Canadian Model
AEP Model
Chinese Model
Japanese Model
SUPPLEMENT-2
File this supplement with the service manual.
(09-497)
• Regarding half completion
inspection equipment modification
9-852-144-82
SAL300F28G
(2.8/300 G) (300mm F2.8 G)
This supplement-2 is the method for making the half completion inspection of SAL300F28G possible by
modifying the SSM HALF COMPLETION JIG: J-6082-662-A that is used for SAL2470Z and SAL1635Z.
This SUPPLEMENT-2 is the revised version
of SUPPLEMENT-1.
Replace the SUPPLEMENT-1 (9-852-144-81)
with the SUPPLEMENT-2.
— 2 —
SAL300F28G (2.8/300 G) (300mm F2.8 G)
English
[Modification method]
Note:
When using SSM HALF COMPLETION JIG as for SAL2470Z or SAL1635Z, the three lead wires below are not used, therefore
insulate the tip of these lead wires.
1. Remove the top cover of SSM HALF COMPLETION JIG by removing four screws.
2. Connect the three lead wires to 6(GND), 7, 8Pin of USB-1208LS.
3. Organize the lead wires as shown below, and pull those out through the gap in the Encoder connector.
4. Mount the top cover of SSM HALF COMPLETION JIG by tightening up four screws.
Loose
Tighten
— 3 —
SAL300F28G (2.8/300 G) (300mm F2.8 G)
[Connection method in the half completion inspection]
Note:
The modification of SSM HALF COMPLETION JIG (J-6082-662-A) should be completed.
1. Do the trial checking lens assembly as shown Fig.1.
(Outer Barrel and Focus Ring should be removed)
2. Solder the lead wires of the modified HALF COMPLETION JIG to the MM board unit of a checking lens and to the DC-DC board unit
as shown Fig.2.
3. Connect equipment and checking lens as shown Fig.3.
HALF COMPLETION JIG
Lens
FINISHED INSPECTION JIG
DC-DC board unit
MM board unit
Lead wire of the modifed one
— 4 —
SAL300F28G (2.8/300 G) (300mm F2.8 G)
[How to select ActuatorChecker with HALF COMPLETION JIG in half completion inspection]
Note 1: 
The connection in the half completion inspection should be completed.
Note 2: 
The lens adjustment program (ActuatorChecker) Ver3.08 or later is needed.
1. Start up "ActuatorChecker"
2. Click the  Set up  button.
3. When "Half" of SAL300F28G is selected, the AD TYPE appears.
4. Select Type I or II (It is changed by click) with reference to the below.
Description for AD TYPE
 AD TYPE: I
 Select if using the HALF COMPLETION JIG (J-6082-692-A)
 AD TYPE: II
 Select if using the modified SSM HALF COMPLETION JIG (J-6082-662-A)
5. Click the  OK  button.
*
It appears after selecting the AD TYPE: I
(HALF COMPLETION JIG (J-6082-692-A))
*
It appears after selecting the AD TYPE: II
(SSM HALF COMPLETION JIG (J-6082-
662-A))
— 5 —
SAL300F28G (2.8/300 G) (300mm F2.8 G)
[Focus brush position adjustment (Completion inspection)]
1. Do the trial checking lens assembly as shown Fig.1.
(Outer Barrel and Focus Ring should be removed.)
Note:
 Go on to perform it after the half completion inspection.
2. Perform in the "Search Focus Adjustment Point" of the completion inspection.
Fig. 1
— 6 —
SAL300F28G (2.8/300 G) (300mm F2.8 G)
Japanese
半完成検査器改造について
SSM半完検査治具:
J-6082-662-A (SAL2470Z, SAL1635Zに使用) に改造を行う事によりSAL300F28Gの半完成検査を可能と
する方法を下記に示します。
【改造方法】
注意:
本来使用機種のSAL2470Z、SAL1635ZのSSM半完成検査冶具として使用する場合には、下記リード線(3本)は使用
しないため、リード線先端を絶縁してください。
1. SSM半完成検査冶具の上カバーをネジ4本で取り外す。
2. USB-1208LSの6(GND)、7、8Pin にリード線を接続する(3本)
3. リード線を図のように整理し、Encoder コネクタの隙間から引き出す。
4. SSM半完成検査冶具の上カバーをネジ4本で取り付ける。
— 7 —
SAL300F28G (2.8/300 G) (300mm F2.8 G)
【 半完成検査時の接続方法 】
注意:
SSM半完成検査治具(J-6082-662-A)の改造が完了していることを確認してください。
1. 被検レンズをFig. 1のように仮組 ( 固定保持環、距離環が外れた状態 ) する。
2. 半完成検査治具 ( 改造品 ) のリード線を被検レンズのMM基板ユニットとDC-DC基板ユニットにFig. 2のように半田付け
する。
3. 使用機器および被検レンズをFig.3のように接続する。
— 8 —
SAL300F28G (2.8/300 G) (300mm F2.8 G)
【 半完成検査時の半完成検査治具による ActuatorChecker の選択方法  】
注意1:
半完成検査時の接続が完了していること。
注意2:
レンズ調整プログラム(ActuatorChecker) Ver3.08 以降が必要です。
1. ActuatorCheckerを起動する。
2. 設定 ボタン をクリックする。
3. SAL300F28Gの Half を選択した場合は、AD TYPE が表示される。
4. 下記を参考にTypeⅠまたはⅡを選択(クリック毎に変わる)する。
 
AD TYPEの説明
 AD TYPE:Ⅰ
 半完成検査冶具(J-6082-692-A)を使用する場合
 AD TYPE:Ⅱ
 SSM半完成検査冶具(J-6082-662-A)の改造品を使用する場合
5. OK をクリックする。
*
半完成検査冶具(J-6082-692-A)を使用する場合
*
SSM半完成検査冶具(J-6082-662-A)を使用する場合
— 9 —
SAL300F28G (2.8/300 G) (300mm F2.8 G)
【フォーカスブラシ位置調整 ( 完成検査 )】
1. 被検レンズをFig. 1のように仮組  ( 固定保持環、距離環が外れた状態 ) する。
注意:
半完成検査からの続きで行ってください。
2. 完成検査の 「フォーカス調整端探査」 にて行う。
Fig. 1
— 9 —
SAL300F28G (2.8/300 G) (300mm F2.8 G)
【フォーカスブラシ位置調整 ( 完成検査 )】
1. 被検レンズをFig. 1のように仮組  ( 固定保持環、距離環が外れた状態 ) する。
注意:
半完成検査からの続きで行ってください。
2. 完成検査の 「フォーカス調整端探査」 にて行う。
Fig. 1

Download Sony SAL300F28G (serv.man4) Service Manual (Repair Manual)

Here you can view online and download Sony SAL300F28G (serv.man4) Service Manual in PDF. SAL300F28G (serv.man4) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sony SAL300F28G (serv.man4) Digital Camera. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.