AVR 265 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 18

Read Harman Kardon AVR 265 EMC - CB Certificate online

 
Page 14 of 45
 
Report No.: 163977
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
8.21 
Bridging components comply with clause 14  
C904 capacitor, bridging  
contact gaps of the mains relay 
Certified component. 
See appended table, list of 
critical components. 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltage exceeding 
1000V ac or 1500V dc. 
N/A 
9.1.1.1 
a) Open circuit voltages  
Mains input voltage >35 Vac, 
see below. 
— 
 
b) Touch current measured from terminal devices 
using the network in annex D  ................................. :
U2: Max. 0.03Vpeak  
(Tested at 264V)  
 
Only U2 have been recorded 
due to the use of a linear 
transformer in power supply. 
 
c) Discharge not exceeding 45 μC  
No part or contact of a  
terminal with stored voltages 
between 60 V – 15 kV. 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
No part or contact of a terminal 
with stored voltages exceeding 
15 kV. 
N/A 
9.1.1.2 
Test with test finger and test probe  
No access to hazardous 
live parts 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers  
No live shafts knobs, handles 
or levers. 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin  
No access for the test pin. 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
Does not reach hazardous 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
Does not reach hazardous 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set controls. 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
See below 
N/A 
 
If C is not greater than 0,1 μF no test needed  
< 0.1uF 
 
Page of 84
Display

Click on the first or last page to see other AVR 265 service manuals if exist.