AVR 265 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 22

Read Harman Kardon AVR 265 EMC - CB Certificate online

 
Page 18 of 45
 
Report No.: 163977
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
14 Components 
 
14.1 Resistors 
 
 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
No such resistors 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
Not used. 
N/A 
 Resistors 
separately approved  ............................... :
 
N/A 
14.2 
Capacitors and RC units  
 
 
Capacitors separately approved  : 
Yes, see below 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition …:
No Y capacitors. 
N/A 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition …:
Capacitors C904 certified  
according to IEC 60384-14 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ...................... :
No such capacitors 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC60384-1, 4.38 category B or better : 
Several E. cap. Vol. >1750mm
3
 
but metal cases. 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 4.38 
category B or better  ................................................ :
Several E. cap. Vol. >1750mm
3
 
but metal cases. 
N/A 
 
Shielded by a barrier acc. To 20.1.4/ table 21 or metal:
 
N/A 
14.3 
Inductors and windings  
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
Transformers evaluated 
according to 14.3.3, 14.3.4 
and 14.3.5. 
14.3.1 
Transformers and inductors marked with 
manufacturer’s name and type  ............................... :
Adequate marking applied. 
Manufacturer`s ID and type no. 
 
Transformers and inductors separately approved.: 
No 
N/A 
14.3.2 General 
 
Isolating transformers 
 
Insulation material complies with clause 20.1.4  
Considered. The insulation 
material of isolating transf. 
complies with flammability 
category of Table 21. 
14.3.3 
Constructional requirements  
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
(see appended table 13) 
Page of 84
Display