Read Harman Kardon AVR 265 EMC - CB Certificate online
Page 18 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14 Components
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
Not used.
N/A
Resistors
separately approved ............................... :
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved :
Yes, see below
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition …:
No Y capacitors.
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition …:
Capacitors C904 certified
according to IEC 60384-14
according to IEC 60384-14
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such capacitors
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better :
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better :
Several E. cap. Vol. >1750mm
3
but metal cases.
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ................................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ................................................ :
Several E. cap. Vol. >1750mm
3
but metal cases.
N/A
Shielded by a barrier acc. To 20.1.4/ table 21 or metal:
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5.
according to 14.3.3, 14.3.4
and 14.3.5.
P
14.3.1
Transformers and inductors marked with
manufacturer’s name and type ............................... :
manufacturer’s name and type ............................... :
Adequate marking applied.
Manufacturer`s ID and type no.
Manufacturer`s ID and type no.
P
Transformers and inductors separately approved.:
No
N/A
14.3.2 General
Isolating transformers
P
Insulation material complies with clause 20.1.4
Considered. The insulation
material of isolating transf.
complies with flammability
category of Table 21.
material of isolating transf.
complies with flammability
category of Table 21.
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table 13)
P