AVR 265 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 15

Read Harman Kardon AVR 265 EMC - CB Certificate online

 
Page 11 of 45
 
Report No.: 163977
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
6 Hazardous 
radiation 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
No ionizing radiation 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  ..... :
No laser radiation 
N/A 
 
Emission limits under fault conditions  ..................... :
 
N/A 
 
Heating under normal operating conditions 
 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
No fuse links operate during 
normal operating operation. 
7.1.1 
Temperature rise of accessible parts  
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier  
(see appended table 7.1) 
7.1.4 
Temperature rise of windings  
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
See appended table 7.2 for 
AC connector CN91 and 
CN92. 
 
Constructional requirements with regard to the protection against electric shock 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
Considered 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
Operation “By hand” not 
possible. 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
No hygroscopic materials 
used 
N/A 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand 
No live terminals or parts  
removable by hand. 
N/A 
8.5 
Class I equipment  
Class II equipment 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
Page of 84