Read Harman Kardon AVR 265 EMC - CB Certificate online
Page 15 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger result
in no hazard.
in no hazard.
P
b) Test hook of fig. 4 for 10 s (20 N)
Test with test hook result
in no hazard.
in no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
Tested with 100N result
in no damaged
in no damaged
P
9.2
No hazard after removing a cover by hand
No cover removable by hand
N/A
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
Basic and resistance insulation;
Min. 100MΩ after surge test
Min. 100MΩ after surge test
P
10.2 Humidity
treatment
48 h or 120 h ........................... :
Performed for 120 h at temp.
40
40
o
C and humidity 93%
P
10.3
Insulation resistance and dielectric strength
between mains terminals
between mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
Class II apparatus
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
11 Fault
conditions
11.1
No shock hazard under fault condition
No electric shock hazard under
fault conditions.
fault conditions.
P
11.2
Heating under fault condition
(see appended table 11.2)
P
Flames extinguish within 10 seconds
No flames
P
No hazard from softening solder
No softening solder
P
Soldered terminations not used as protective
mechanism
mechanism
No protective mechanism.
P
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table 11.2)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
No exceeding the limits of
Table 3.
Table 3.
N/A