Read Harman Kardon AVR 265 EMC - CB Certificate online
Page 9 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
3 General
requirements
Safety class of the apparatus ..................................
Class II apparatus
P
4 General
test
conditions
4.1.4 Ventilation
instructions
require the use of the test
box
Tested in a open space
according to manufacturer’s
instructions
according to manufacturer’s
instructions
N/A
5 Marking
and
instructions
Comprehensible and easily discernible
On front and rear side of the
enclosure
enclosure
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / sprit
P
5.1
a) Identification, maker ............................................ :
Trade mark:
See copy of marking plate
P
b) Model number or type reference .......................... :
AVR 265/230
See copy of marking plate.
See copy of marking plate.
P
c) Class II symbol if applicable ................................ :
Class II symbol is applied in
according to IEC 60417-5172
according to IEC 60417-5172
P
d)
Nature
of supply.................................................... :
a. c. symbol is applied in
according to IEC 60417-5032
according to IEC 60417-5032
P
e) Rated supply voltage ........................................... :
220-240V and
AC-symbol ( ~ ) used.
AC-symbol ( ~ ) used.
P
f) Mains frequency if safety dependant ................... :
50/60Hz
P
g) Rated current or power consumption for apparatus
supplied by supply apparatus for general use ............ :
supplied by supply apparatus for general use ............ :
The apparatus is connection
to an a. c. mains supply.
to an a. c. mains supply.
N/A
Measured current or power consumption ............... :
N/A
Deviation % (max 10%) .......................................... :
N/A
h) Power consumption marking for apparatus other
than single phase ..................................................... :
than single phase ..................................................... :
The apparatus is connection
to an a. c. mains supply.
to an a. c. mains supply.
N/A
i) Rated current or power consumption for apparatus
intended for connection to an a.c. mains supply ......... :
intended for connection to an a.c. mains supply ......... :
420W
P
Measured current or power consumption ............... :
346.1W
(refer to appended table 7.1)
(refer to appended table 7.1)
P
Deviation % (max 10%) .......................................... :
Not exceed the marked value
P