Read Harman Kardon AVR 265 EMC - CB Certificate online
Page 13 of 45
Report No.: 163977
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
Single insulation, but safely
anchored.
anchored.
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Double insulated according to
8.9 and 10.3
8.9 and 10.3
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Single insulation, but safely
anchored.
anchored.
N/A
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Inlet connected wires
hooked-in before soldered.
Other primary wires connected
with multi-contact housing.
hooked-in before soldered.
Other primary wires connected
with multi-contact housing.
P
Vibration
test
carried out ......................................... :
See 12.12
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (push/pull test 50 N
for 10 s)
for 10 s)
Covers adequately fastened
with screws.
with screws.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Wires safely anchored away
from parts with high
temperature
from parts with high
temperature
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such winding wire used
N/A
8.18
Endurance test as required by 8.17
No such insulation winding is
used.
used.
N/A
8.19
Disconnection from the mains
See below.
P
8.19.1 Disconnect
device
Appliance coupler is used as
disconnect devices
disconnect devices
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No all-pole switch or circuit
breaker.
breaker.
N/A
8.19.2
Mains switch ON indication
Indicator lamp or display lit-on.
P
8.20
Switch not fitted in the mains cord
No switch in the mains cord.
P