AVR 134 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 24

Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online

 
Page 23 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
2. Stand-by transformer core 
25.1 
85 
3. RLY301 body 
29.2 
55 
4. Inlet inside 
17.9 
45 
5. AC cord wire terminal(CP306) 
22.4 
50 
6. D111 body 
44.5 
7. D112 body 
50.3 
8. C180 body 
24.0 
9. IC103 heat-sink 
63.0 
10. IC112 heat-sink 
38.0 
11. IC104 body 
52.9 
12. Q206C body 
61.4 
13. Front panel 
8.0 
60 
14. Main heat-sink left 
52.5 
15. Main heat-sink center 
62.1 
16. Main heat-sink right 
55.3 
17. IC108 body 
23.3 
18. Enclosure above main transformer 
20.3 
40 
19. Enclosure above main heat-sink 
26.9 
40 
 
Winding temperature rise measurements 
 
Ambient temperature t1 (
o
C)  .................................. :
Same as below 
— 
 
Ambient temperature t2 (
o
C)  .................................. :
Same as below 
— 
Temperature rise dT of winding: 
R
1
 (
Ω)
R
2
 (
Ω) 
t1 (°C)
t2 (°C)
dT (K) 
Limit dT 
(K) 
Insulation 
class 
Mains trans primary (253 V) 
7.259 
8.983 
25.9 
24.3 
63.4 
85 
Stand-by trans primary (253 V) 
3849 
4247 
25.9 
24.3 
28.5 
85 
 
 
7.2 
TABLE: softening temperature of thermoplastics 
Temperature T of part 
T – normal condi-
tions (
o
C) 
T - fault condi-
tions (
o
C) 
T softening 
(
o
C) 
Connector (CP306) 
46.6 
> 150 
- CP306 is the same material as CP305 and CP304 
 
10.3 
TABLE: insulation resistance measurements 
Insulation resistance R between: 
R (M
Ω) 
Required R (M
Ω) 
Page of 62
Display