Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online
Page 27 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
39. C301
S/C 264
V 2 h, 21 min
0.04
Immediately protection circuit(RLY301)
operated. Primary winding of standby
transformer heated up to 47,3 K and
stabilized. NCD. No hazard.
operated. Primary winding of standby
transformer heated up to 47,3 K and
stabilized. NCD. No hazard.
40. IC300(In – Out) S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
41. C300
S/C 264
V 49 min
0.03
Immediately protection circuit(RLY301)
operated. IC300 heated up to 17,3 K. NCD.
No hazard.
operated. IC300 heated up to 17,3 K. NCD.
No hazard.
42. C154
S/C 264
V 36 min
0.20
REG101 heated up to 29,1 K and stabilized.
NCD. No hazard.
NCD. No hazard.
43. C151
S/C 264
V 41 min
0.19
REC100 heated up to 24,8 K and stabilized.
NCD. No hazard.
NCD. No hazard.
44. Q205FR (B – C)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
45. Q205FR (C – E)
S/C 264
V
5 s
0
Immediately R220FR, R221FR, R222FR,
R223FR smoked for 1 s and opened. R219FR
smoked for 1 sec and damaged. Q206FR
shorted. Protection circuit(RLY301) operated.
NB. No hazard.
R223FR smoked for 1 s and opened. R219FR
smoked for 1 sec and damaged. Q206FR
shorted. Protection circuit(RLY301) operated.
NB. No hazard.
46. Q205FR (B – E)
S/C 264
V 33 min
0.19
Normal operation. NCD. No hazard.
47. Q206FR (B – C)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
48. Q206FR (C – E)
S/C 264
V
4 s
0
Immediately R220FR, R221FR, R222FR,
R223FR smoked for 1 s and opened.
R218FR damaged. Q205FR shorted.
Protection circuit(RLY301) operated. NB. No
hazard.
R223FR smoked for 1 s and opened.
R218FR damaged. Q205FR shorted.
Protection circuit(RLY301) operated. NB. No
hazard.
49. Q206FR (B – E)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
50. Q203FR (B – E)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
51. Q203FR (B – C)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
52. Q203FR (C – E)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
53. Q202FR (B – C)
S/C 264
V
5 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
54. Q202FR (B – E)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
55. Q202FR (C – E)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
56. Q201FR (B – C)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.