AVR 134 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 27

Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online

 
Page 26 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
17. C222 
S/C 264 
V 1 h, 08 min
0.22 
IC111 heated up to 67.2 K and stabilized. 
NCD. No hazard. 
18. IC112(In – Out)  S/C 264 
V  38 min 
0.20 
REC100 heated up to 18,1 K and stabilized. 
NCD. No hazard. 
19. C219 
S/C 264 
V  44 min 
0.22 
IC112 heated up to 69,7 K and stabilized. 
NCD. No hazard. 
20. IC108(In – Out)  S/C 264 
V  45 min 
0.19 
Normal operation. NCD. No hazard. 
21. C223 
S/C 264 
V  39 min 
0.21 
IC108 heated up to 51.3 K and stabilized. 
NCD. No hazard. 
22. C207
 
S/C 264 
V  29 min 
0.16 
Immediately R207, R208 smoked for 1 s and 
opened. NB. No hazard. 
23. IC103 (In – Out)
 
S/C 264 
4 s 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
24. IC104 (In – Out)
 
S/C 264 
3 s 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
25. C204
 
S/C 264 
5 s 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
26. C205
 
S/C 264 
3 s 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
27. D118
 
S/C 264 
V  32 min 
0.19 
Normal operation. NCD. No hazard. 
28. C176 
S/C 264 
3 s 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
29. C264 
S/C 264 
V  27 min 
0.19 
Normal operation. NCD. No hazard. 
30. C175 
S/C 264 
V  34 min 
0.19 
Normal operation. NCD. No hazard. 
31. ZD102
 
S/C 264 
V  39 min 
0.19 
Normal operation. NCD. No hazard. 
32. IC105(4 – 8) 
S/C 264 
4 s 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
33. IC105(4 – 5) 
S/C 264 
V  28 min 
0.19 
Normal operation. NCD. No hazard. 
34. IC105(4 – 6) 
S/C 264 
V  30 min 
0.19 
Normal operation. NCD. No hazard. 
35. IC105(4 – 7) 
S/C 264 
V  26 min 
0.19 
Normal operation. NCD. No hazard. 
36. D303 
S/C 264 
V 2 h, 10 min
0.03 
Immediately protection circuit(RLY301) 
operated. Priwinding of standby transformer 
heated up to 26,9 K and stabilized. NCD. No 
hazard. 
37. D306 
S/C  264 V  1 h, 54 min
0.03 
Immediately protection circuit(RLY301) 
operated. Primary winding of standby 
transformer heated up to 47,3 K and 
stabilized. NCD. No hazard. 
38. C302 
S/C 264 
V 1 h, 55 min
0.04 
Immediately protection circuit(RLY301) 
operated. Primary winding of standby 
transformer heated up to 47,1 K and 
stabilized. NCD. No hazard. 
Page of 62