Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online
Page 26 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
17. C222
S/C 264
V 1 h, 08 min
0.22
IC111 heated up to 67.2 K and stabilized.
NCD. No hazard.
NCD. No hazard.
18. IC112(In – Out) S/C 264
V 38 min
0.20
REC100 heated up to 18,1 K and stabilized.
NCD. No hazard.
NCD. No hazard.
19. C219
S/C 264
V 44 min
0.22
IC112 heated up to 69,7 K and stabilized.
NCD. No hazard.
NCD. No hazard.
20. IC108(In – Out) S/C 264
V 45 min
0.19
Normal operation. NCD. No hazard.
21. C223
S/C 264
V 39 min
0.21
IC108 heated up to 51.3 K and stabilized.
NCD. No hazard.
NCD. No hazard.
22. C207
S/C 264
V 29 min
0.16
Immediately R207, R208 smoked for 1 s and
opened. NB. No hazard.
opened. NB. No hazard.
23. IC103 (In – Out)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
24. IC104 (In – Out)
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
25. C204
S/C 264
V
5 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
26. C205
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
27. D118
S/C 264
V 32 min
0.19
Normal operation. NCD. No hazard.
28. C176
S/C 264
V
3 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
29. C264
S/C 264
V 27 min
0.19
Normal operation. NCD. No hazard.
30. C175
S/C 264
V 34 min
0.19
Normal operation. NCD. No hazard.
31. ZD102
S/C 264
V 39 min
0.19
Normal operation. NCD. No hazard.
32. IC105(4 – 8)
S/C 264
V
4 s
0
Immediately protection circuit(RLY301)
operated. NCD. No hazard.
operated. NCD. No hazard.
33. IC105(4 – 5)
S/C 264
V 28 min
0.19
Normal operation. NCD. No hazard.
34. IC105(4 – 6)
S/C 264
V 30 min
0.19
Normal operation. NCD. No hazard.
35. IC105(4 – 7)
S/C 264
V 26 min
0.19
Normal operation. NCD. No hazard.
36. D303
S/C 264
V 2 h, 10 min
0.03
Immediately protection circuit(RLY301)
operated. Priwinding of standby transformer
heated up to 26,9 K and stabilized. NCD. No
hazard.
operated. Priwinding of standby transformer
heated up to 26,9 K and stabilized. NCD. No
hazard.
37. D306
S/C 264 V 1 h, 54 min
0.03
Immediately protection circuit(RLY301)
operated. Primary winding of standby
transformer heated up to 47,3 K and
stabilized. NCD. No hazard.
operated. Primary winding of standby
transformer heated up to 47,3 K and
stabilized. NCD. No hazard.
38. C302
S/C 264
V 1 h, 55 min
0.04
Immediately protection circuit(RLY301)
operated. Primary winding of standby
transformer heated up to 47,1 K and
stabilized. NCD. No hazard.
operated. Primary winding of standby
transformer heated up to 47,1 K and
stabilized. NCD. No hazard.
Click on the first or last page to see other AVR 134 (serv.man2) service manuals if exist.