AVR 134 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 23

Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online

 
Page 22 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
13. Front panel 
5.8 
60 
14. Main heat-sink left 
55.3 
15. Main heat-sink center 
61.0 
16. Main heat-sink right 
56.9 
17. IC108 body 
24.4 
18. Enclosure above main transformer 
20.3 
40 
19. Enclosure above main heat-sink 
29.6 
40 
 
Winding temperature rise measurements 
 
Ambient temperature t1 (
o
C)  .................................. :
Same as below 
— 
 
Ambient temperature t2 (
o
C)  .................................. :
Same as below 
— 
Temperature rise dT of winding: 
R
1
 (
Ω)
R
2
 (
Ω) 
t1 (°C)
t2 (°C)
dT (K) 
Limit dT 
(K) 
Insulation 
class 
Mains trans primary (264 V) 
7.538 
9.442 
24.7 
26.5 
63.7 
85 
Stand-by trans primary (264 V) 
4054 
4514 
24.7 
26.5 
27.6 
85 
 
Operating conditions 
- test signal : pink noise signal wave 
- 1/8 of rated output 
- connected  6 
Ω load to front, center and surround terminals 
- supply : 207 V ~ 50 Hz, 253 V 
∼ 50 Hz  
- wooden test box : not applicable (see Cl. 4.1.4) 
Un (V) 
Fn (Hz) 
In (A) 
Pn (W) 
Pout (W) 
230 50 
1.96 
390.7 
rated 
output 
207 
50 
0.88 
140.7 
1/8 rated output 
230 
50 
0.90 
158.1 
1/8 rated output *) 
253 
50 
0.92 
176.2 
1/8 rated output 
230 50 
0.004 
0.8 
stand-by 
*): 2,29 W x 5 
 
Loudspeaker impedance (
Ω)  ............
Ω — 
 
Several loudspeaker systems 
5 channel stereo 
 
Marking of loudspeaker terminals 
SPEAKER ; FRONT( 6
Ω ), SURROUND( 6Ω ), 
CENTER( 6
Ω ) 
 
Monitored point: 
dT (K) 
  Limit dT (K) 
 
253 V 
∼ 50 Hz 
 
1. Main transformer core 
48.5 
85 
Page of 62
Display

Click on the first or last page to see other AVR 134 (serv.man2) service manuals if exist.