Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online
Page 22 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
13. Front panel
5.8
60
14. Main heat-sink left
55.3
-
15. Main heat-sink center
61.0
-
16. Main heat-sink right
56.9
-
17. IC108 body
24.4
-
18. Enclosure above main transformer
20.3
40
19. Enclosure above main heat-sink
29.6
40
Winding temperature rise measurements
P
Ambient temperature t1 (
o
C) .................................. :
Same as below
—
Ambient temperature t2 (
o
C) .................................. :
Same as below
—
Temperature rise dT of winding:
R
1
(
Ω)
R
2
(
Ω)
t1 (°C)
t2 (°C)
dT (K)
Limit dT
(K)
Insulation
class
Mains trans primary (264 V)
7.538
9.442
24.7
26.5
63.7
85
E
Stand-by trans primary (264 V)
4054
4514
24.7
26.5
27.6
85
E
Operating conditions
- test signal : pink noise signal wave
- 1/8 of rated output
- connected 6
Ω load to front, center and surround terminals
- supply : 207 V ~ 50 Hz, 253 V
∼ 50 Hz
- wooden test box : not applicable (see Cl. 4.1.4)
Un (V)
Fn (Hz)
In (A)
Pn (W)
Pout (W)
230 50
1.96
390.7
rated
output
207
50
0.88
140.7
1/8 rated output
230
50
0.90
158.1
1/8 rated output *)
253
50
0.92
176.2
1/8 rated output
230 50
0.004
0.8
stand-by
*): 2,29 W x 5
Loudspeaker impedance (
Ω) ............
6
Ω —
Several loudspeaker systems
5 channel stereo
P
Marking of loudspeaker terminals
SPEAKER ; FRONT( 6
Ω ), SURROUND( 6Ω ),
CENTER( 6
Ω )
P
Monitored point:
dT (K)
Limit dT (K)
253 V
∼ 50 Hz
1. Main transformer core
48.5
85
Click on the first or last page to see other AVR 134 (serv.man2) service manuals if exist.