Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online
Page 18 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No screw terminals
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
No cover-fixing devices
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
unlikely to become disconnected
Test conducted by a pull of 2 N
P
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
No picture tube
N/A
Picture tube separately approved to 18.1 ...............
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically protected tubes > 16 cm used with
protective screen
protective screen
N/A
Protective film as part of implosion protection:
edges covered by enclosure
edges covered by enclosure
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
19
STABILITY AND MECHANICAL HAZARDS
P
Mass of the equipment exceeding 7 kg ................. : Approximately 8.4 kg
P
Apparatus intended to be fastened in place –
suitable instructions
suitable instructions
No N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
Tested
P
19.2
100 N force applied vertically downwards
P
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability.
to point of least stability.
N/A
19.4
Edges or corners not hazardous
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
No the glass breaks or cracks
N/A