Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online
Page 21 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
Same as below
—
Position of the functional switch (W) ...................... :
Front
—
Operating conditions
- test signal : pink noise signal wave
- 1/8 of rated output
- connected 6
Ω load to front, center and surround terminals
- supply : 216 V ~ 50 Hz, 264 V
∼ 50 Hz
- wooden test box : not applicable (see Cl. 4.1.4)
Un (V)
Fn (Hz)
In (A)
Pn (W)
Pout (W)
240 50
1.96
406.4
rated
output
216
50
0.89
148.9
1/8 rated output
240
50
0.93
171.1
1/8 rated output *)
264
50
0.98
198.8
1/8 rated output
240 50
0.004
0.8
stand-by
*): 2,47 W x 5
Loudspeaker impedance (
Ω) ............
6
Ω —
Several loudspeaker systems
5 channel stereo
P
Marking of loudspeaker terminals
SPEAKER ; FRONT( 6
Ω ), SURROUND( 6Ω ),
CENTER( 6
Ω )
P
Monitored point:
dT (K)
Limit dT (K)
264 V
∼ 50 Hz
1. Main transformer core
47.7
85
2. Stand-by transformer core
24.0
85
3. RLY301 body
28.3
55
4. Inlet inside
16.2
45
5. AC cord wire terminal(CP306)
20.6
50
6. D111 body
46.5
-
7. D112 body
51.6
-
8. C180 body
22.0
-
9. IC103 heat-sink
49.0
-
10. IC112 heat-sink
35.9
-
11. IC104 body
51.6
-
12. Q206C body
62.5
-