Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online
Page 15 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
15 TERMINALS
P
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
(see appended table 14)
P
15.1.2
Connectors for antenna, earth, audio, video or data:
N/A
No risk of insertion in mains socket-outlets
N/A
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No terminals like
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
No terminals like
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II equipment
N/A
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to earth
output voltage: output circuit not connected to earth
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω at 25 A ................... :
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
No permanently connected
apparatus
apparatus
N/A
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N/A
15.3.2
Reliable connection of non-detachable cords:
N/A
Not soldered to conductors of a printed circuit
board
board
Crimped contacts within plug
connector
connector
P
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
Wires are crimped two times to
the contact and provided with a
two pole-connector
the contact and provided with a
two pole-connector
P
Wire secured by additional means to the conductor Wires insulators are crimped
P
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
None N/A
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
None N/A