AVR 134 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 17

Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online

 
Page 16 of 34 
Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
Crimped the insulators and 
conductors 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
 N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16 No terminals like 
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
No terminals like 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 N/A 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
 N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
No terminals like 
N/A 
 
Terminals located and shielded: test with 8 mm 
strand 
Crimped contacts within plug 
connector 
15.4 
Devices forming a part of the mains plug 
 
N/A 
15.4.1 
No undue strain on mains socket-outlets 
No devices like 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) 
 N/A 
 
16 
EXTERNAL FLEXIBLE CORDS 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  ............................................................ :
PVC sheathed (refer to 
appended table 14) 
 
Non-detachable cords for Class I have 
green/yellow core for protective earth 
Class II 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
0.98 A, Cl.7.1 at 264 V 
: 2 
× 
0.75 mm
2
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 
No interconnection cord 
N/A 
Page of 62
Display

Click on the first or last page to see other AVR 134 (serv.man2) service manuals if exist.