Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online
Page 16 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
Crimped the insulators and
conductors
conductors
P
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16 No terminals like
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
No terminals like
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
No terminals like
N/A
Terminals located and shielded: test with 8 mm
strand
strand
Crimped contacts within plug
connector
connector
P
15.4
Devices forming a part of the mains plug
N/A
15.4.1
No undue strain on mains socket-outlets
No devices like
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N/A
16
EXTERNAL FLEXIBLE CORDS
P
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
PVC sheathed (refer to
appended table 14)
appended table 14)
P
Non-detachable cords for Class I have
green/yellow core for protective earth
green/yellow core for protective earth
Class II
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
0.98 A, Cl.7.1 at 264 V
∼
: 2
×
0.75 mm
2
:
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
No interconnection cord
N/A
Click on the first or last page to see other AVR 134 (serv.man2) service manuals if exist.