Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
Coil formers and partition walls > 0,4 mm
Between primary and
secondary windings:
main transformer: min. 1,0
mm, stand-by transformer: min.
1,7 mm.
secondary windings:
main transformer: min. 1,0
mm, stand-by transformer: min.
1,7 mm.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II transformers provided
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
Isolating transformers provided
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Bobbin provided
P
Coil formers and partition walls > 0,4 mm
Between primary winding and
core:
main transformer: min. 0.9
mm, stand-by transformer: min.
1.0 mm
core:
main transformer: min. 0.9
mm, stand-by transformer: min.
1.0 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II transformers provided
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
(see appended table)
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
P
Protective devices used within their ratings
250V
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Between conductors of fuse
holders: F301: min. 4.4 mm;
holders: F301: min. 4.4 mm;
P
14.5.1.1
a) Thermal cut-outs separately approved
No thermal cut-outs
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
Certified thermal fuse provided
in the main transformer
in the main transformer
P