Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
(see appended table) 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
b) Resistors separately approved  ........................... : No 
N/A 
14.2 
Capacitors and RC units 
C304 
 
Capacitors separately approved 
Yes (by VDE or SEMKO) 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  ... : No 
N/A 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  ... : X2 (C304: 0.0047 
μF / 250 V) 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ...................... :
 N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better  ....................................................................... :
All capacitors do not exceed 
1750 mm³ and except for electrical 
capacitors (C179, C180) 
connected to secondary circuit 
and shielded by metal case
 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better  ........................................ :
All capacitors do not exceed 
1750 mm³ and except for electrical 
capacitors (C179, C180) 
connected to secondary circuit 
and shielded by metal case
 
N/A 
 
Shielded by a barrier to V-0 or metal  ...................... : Yes
 (shielded by metal case : 
C179, C180: max. 43963 mm³ )
 
14.3 
Inductors and windings 
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 P 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ............................... :
The transfomers are marked 
with the trademark and type 
designation as appended table. 
 
Transformers and inductors separately approved  . : No (tested in appliance) 
N/A 
14.3.2 General 
 
14.3.3 Constructional 
requirements Bobbin 
provided 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Bobbin provided 
Page of 62