Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
(see appended table)
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
b) Resistors separately approved ........................... : No
N/A
14.2
Capacitors and RC units
C304
P
Capacitors separately approved
Yes (by VDE or SEMKO)
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ... : No
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ... : X2 (C304: 0.0047
μF / 250 V)
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
All capacitors do not exceed
1750 mm³ and except for electrical
capacitors (C179, C180)
connected to secondary circuit
and shielded by metal case
1750 mm³ and except for electrical
capacitors (C179, C180)
connected to secondary circuit
and shielded by metal case
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
All capacitors do not exceed
1750 mm³ and except for electrical
capacitors (C179, C180)
connected to secondary circuit
and shielded by metal case
1750 mm³ and except for electrical
capacitors (C179, C180)
connected to secondary circuit
and shielded by metal case
N/A
Shielded by a barrier to V-0 or metal ...................... : Yes
(shielded by metal case :
C179, C180: max. 43963 mm³ )
P
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
The transfomers are marked
with the trademark and type
designation as appended table.
with the trademark and type
designation as appended table.
P
Transformers and inductors separately approved . : No (tested in appliance)
N/A
14.3.2 General
P
14.3.3 Constructional
requirements Bobbin
provided
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Bobbin provided
P