Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online
Page 8 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
Top enclosure: max. 2
× 18
mm
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
Test conducted
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Test conducted
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
0 Vp
P
If C is not greater than 0,1 μF no test needed
< 0.1 μF P
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
Test conducted
P
Test hook of fig. 4 for 10 s (20 N)
Test conducted
P
30 mm diameter test tool for 5 s (100 or 250 N) .... : Applied 100 N
P
9.2
No hazard after removing a cover by hand
No removing a cover by hand
N/A
10 INSULATION
REQUIREMENTS
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
100 M
Ω P
10.2
Humidity treatment 48 h or 120 h ........................... : 120 h, 30 °C, 93 %
P
10.3
Insulation resistance and dielectric strength
between mains teminals
between mains teminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
P
11 FAULT
CONDITIONS
P
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
(see appended table 11.2)
P
No hazard from softening solder
P
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table 11.2)
P