Report Ref. No. 077-204389-000 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60065G 
 
 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
Class II equipment 
N/A 
8.5 
Class I equipment 
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
Class II equipment 
N/A  
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
Class II equipment 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
Double insulated primary wires
 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Main transformer, stand-by 
transformer, relay (RLY301) 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
 
N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
 N/A 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
 
 
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm)  :  
 
Reinforced insulation > 0,4 mm (mm)  .................... : Main transformer, stand-by 
transformer, relay (RLY301) 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22) 
None N/A 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 N/A 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
Double insulation provided 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
 P 
Page of 62