Read Harman Kardon AVR 134 (serv.man2) EMC - CB Certificate online
Page 6 of 34
Report Ref. No. 077-204389-000
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IECEN60065G
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
Class II equipment
N/A
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
Class II equipment
N/A
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
Class II equipment
P
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double insulated primary wires
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Main transformer, stand-by
transformer, relay (RLY301)
transformer, relay (RLY301)
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
N/A
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
P
Reinforced insulation > 0,4 mm (mm) .................... : Main transformer, stand-by
transformer, relay (RLY301)
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
None N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulation provided
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
P