PULSE (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 109

Read JBL PULSE (serv.man6) EMC - CB Certificate online

 
 
- Page 4 of 8 - 
 
 
www.nemko.com 
Report No.   241619 
 
 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
2.6.5.4 
Replace 1st sentence with the following.  
Protective earthing connections of CLASS I 
EQUIPMENT shall make earlier and break later 
than the supply connections in each of the 
following: 
Class III equipment. 
N/A 
2.6.5.8A 
Add the following new clause. after 2.6.5.8A  
 2.6.5.8A Earthing of CLASS 0I EQUIPMENT Plugs 
with a lead wire for earthing shall not be used for 
equipment having a rated voltage exceeding 150V. 
For plugs with a lead wire for earthing, the lead 
wire shall not be earthed by a clip.  
CLASS 0I EQUIPMENT shall be provided with an 
earthing terminal or lead wire for earthing in the 
external location where easily visible. 
Class III equipment. 
N/A 
3.2.3 
Add the following after Table 3A:   
Table 3A applies when cables complying JIS C 
3662 or JIS C 3663 are used.  In case of other 
cables, cable entries shall be so designed that a 
conduit suitable for the cable used can be fitted. 
Class III equipment. 
N/A 
3.2.5.1 
Add the following to the last of first dashed 
paragraph. Or mains cords shall be of the sheathed 
type complying with Appendix 1 of Article 1 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. 
 Add the following to the last of second dashed 
paragraph. Or mains cords shall be of the sheathed 
type complying with Appendix 1 of Article 1 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. 
Delete 1) in Table 3B 
Class III equipment. 
N/A 
3.3.4 
Add the following note to Table 3D:   
Note  For cables other than those complying with 
JIS C 3662 or JIS C 3663, terminals shall be 
suitable for the size of the intended cables. 
Class III equipment. 
N/A 
3.3.7 
Add the following after the first  sentence:   
This requirement is not applicable to the external 
earthing terminal of Class 0I equipment. 
Class III equipment. 
N/A 
4.3.4 
Add the following after the first  sentence:   
This requirement also applies to those connections 
in Class 0I equipment, where CLEARANCE or 
CREEPAGE DISTANCES over BASIC 
INSULATION would be reduced to less than the 
values specified in 2.10. 
Class III equipment. 
N/A 