- Page 5 of 8 -
www.nemko.com
Report No. 241619
Clause
Requirement - Test
Result - Remark
Verdict
5.1.3
Add a note after the first paragraph as follows:
Note – Attention should be drawn to that majority of
three-phase power system in Japan is of delta
connection, and therefore, in that case, test is
conducted using the test circuit from IEC 60990,
figure 13.
Note – Attention should be drawn to that majority of
three-phase power system in Japan is of delta
connection, and therefore, in that case, test is
conducted using the test circuit from IEC 60990,
figure 13.
Class III equipment.
N/A
5.1.6
Replacement: Replace Table 5A.
7.2
Add the following after the paragraph:
However, the separation requirements and tests of
6.2.1 a), b) and c) do not apply to a CABLE
DISTRIBUTION SYSTEM if all of the following
apply:
− the circuit under consideration is a TNV-1
CIRCUIT; and
– the common or earthed side of the circuit is
connected to the screen of the coaxial cable and to
all accessible parts and circuits (SELV, accessible
metal parts and LIMITED CURRENT CIRCUITS, if
any); and
– the screen of the coaxial cable is intended to be
connected to earth in the building installation.
However, the separation requirements and tests of
6.2.1 a), b) and c) do not apply to a CABLE
DISTRIBUTION SYSTEM if all of the following
apply:
− the circuit under consideration is a TNV-1
CIRCUIT; and
– the common or earthed side of the circuit is
connected to the screen of the coaxial cable and to
all accessible parts and circuits (SELV, accessible
metal parts and LIMITED CURRENT CIRCUITS, if
any); and
– the screen of the coaxial cable is intended to be
connected to earth in the building installation.
No CDS and TNV circuit.
N/A