Read JBL PULSE (serv.man6) EMC - CB Certificate online
- Page 2 of 8 -
www.nemko.com
Report No. 241619
Clause
Requirement - Test
Result - Remark
Verdict
1.5. 1
Replace the first paragraph with the follows:
Where safety is involved, components shall comply
either with the requirements of this standard, with
the safety aspects of the relevant JIS component
standard, or IEC component standards in case
there is no applicable JIS component standard is
available. However, a component that falls within
the scope of METI Ministerial ordinance No. 85 is
properly used in accordance with its marked
ratings, requirements of 1.5.4, 2.8.7 and 3.2.5
apply, and in addition, a cord connector of power
supply cord set mating with appliance inlet
complying with the standard sheet of IEC 60320-1,
shall comply with relevant standard sheet of IEC
60320-1.
Replace Note 1 with the following:
Note 1 A JIS or an IEC component standard is
considered relevant only if the component in
question clearly falls within its scope.
Where safety is involved, components shall comply
either with the requirements of this standard, with
the safety aspects of the relevant JIS component
standard, or IEC component standards in case
there is no applicable JIS component standard is
available. However, a component that falls within
the scope of METI Ministerial ordinance No. 85 is
properly used in accordance with its marked
ratings, requirements of 1.5.4, 2.8.7 and 3.2.5
apply, and in addition, a cord connector of power
supply cord set mating with appliance inlet
complying with the standard sheet of IEC 60320-1,
shall comply with relevant standard sheet of IEC
60320-1.
Replace Note 1 with the following:
Note 1 A JIS or an IEC component standard is
considered relevant only if the component in
question clearly falls within its scope.
The component fulfils the
relevant IEC standard.
relevant IEC standard.
N/A
1.5.2
Replace first sentence in the first dashed
paragraph with the following:
- a component that has been demonstrated to
comply with a JIS component standard harmonized
with the relevant IEC component standard, or
where such JIS component standard is not
available, a component that has been
demonstrated to comply with the relevant IEC
component standard shall be checked for correct
application and use in accordance with its rating.
Add a note after the first dashed paragraph as
follows:
Note 1 See 1.7.5A when Type C.14 appliance
coupler rated 10 A per IEC 60320-1 is used with an
equipment rated not more than 125 V and rated
more than 10 A.
Replace first sentence in the third dashed
paragraph as follows:
- where no relevant IEC component standard or JIS
component standard harmonized with the relevant
IEC component standard exists, or where
components are used in circuits not in accordance
with their specified rating, the components shall be
tested under the conditions occurring in the
equipment.
paragraph with the following:
- a component that has been demonstrated to
comply with a JIS component standard harmonized
with the relevant IEC component standard, or
where such JIS component standard is not
available, a component that has been
demonstrated to comply with the relevant IEC
component standard shall be checked for correct
application and use in accordance with its rating.
Add a note after the first dashed paragraph as
follows:
Note 1 See 1.7.5A when Type C.14 appliance
coupler rated 10 A per IEC 60320-1 is used with an
equipment rated not more than 125 V and rated
more than 10 A.
Replace first sentence in the third dashed
paragraph as follows:
- where no relevant IEC component standard or JIS
component standard harmonized with the relevant
IEC component standard exists, or where
components are used in circuits not in accordance
with their specified rating, the components shall be
tested under the conditions occurring in the
equipment.
The component fulfils the
relevant IEC standard.
relevant IEC standard.
N/A