– 11 –
KV-SZ292M31/M50
RM-GA002
2-11.  Connector Assy wire dressing
2-12.  Overall view of rotation coil conn
i) Dress Conn Assy, 7P RGB; Conn Assy, 5P Front In and
Lead Assy, Earth using purse lock Ø 9. Keep wires away from 
heatsinks and high-temperature parts. 
ii) Dress DY Connector; Conn Assy, 4P 200V;  
Conn Assy 4P VM and Conn Assy, 6P using purse 
lock Ø 5 as shown.
Note: Make sure DY connector is inserted securely
--> prevent it from coming out.
Install Rotation Coil as shown.
1) Coil positioned in clockwise direction.
2) Wire is at 3 o'clock position.
CAUTION:
Prevent wires from touching rear cover or any 
enclosures by turning them away from it--> avoid rattle
sound.
2-13.  Overall view of Lead Assy, G2; Lead Assy,
 
Focus and Rotation Coil Conn Dressing
CAUTION:
Prevent wires from touching rear cover or any 
enclosures by turning them away from it--> avoid rattle
sound.
Avoid any stress on Lead Assy, G2; Lead Assy, Focus and
terminal at CN704.
Lead Assy, Earth is behind
Conn Assy, 7P RGB
Purse lock Ø 9
Conn Assy, 7P RGB
Conn Assy, 5P Front In
CN004
DY Conn
Conn Assy, 6P
Conn Assy,
4P 200V
Conn Assy, 4P VM
CN1802
Rotation Coil Conn
Dress Rotation Coil
connector together with Lead
Assy, G2; Lead Assy Focus
and Conn Assy, 4P 200V
using pin, wire A707
A715
A713
Conn Assy, 4P 200V
W7001
Lead Assy, G2
Lead Assy,
Focus
Keep wire away
from R781
Dress purse lock Ø 5 
by using height of 
heatsink as a guide
Use height of
heatsink as a guide
Keep Conn Assy,
4P 200V away from FBT
(min. 10mm)
Make loop of Conn Assy, 7P RGB as large as 
possible when dressing with purse lock
Lead Assy, Earth
Rotation Coil
DY
Wire from Roation Coil
Keep wire away
from R781 and 
heatsinks A713, A715.
Earth Assy,
Coating wires
Rotation coil conn is dressed outside
and below Earth Assy, Coating wires.
Purse lock 
Ø
 9
Conn Assy, 7P RGB
Purse lock Ø 5
Conn Assy
4P
 VM
DY
 Connector
Conn Assy
4P
 200V
Conn Assy
6P
Lead Assy, Earth
Conn Assy, 5P
Keep Conn Assy, 5P Front In wire in an upward
path from CN9201 to where it is dressed with 
purse lock Ø 9. This is to keep it away from 
deflection area.