Read Sony KV-SZ292M31 (serv.man2) Service Manual online
– 14 –
KV-SZ292M31/M50
RM-GA002
CAUTION:
1. Do not overpull the wires during dressing
_> avoid disconnection of wires.
2. Make sure wires are kept away from
sharp edges, heatsinks & other
hight-temperature parts.
1. Do not overpull the wires during dressing
_> avoid disconnection of wires.
2. Make sure wires are kept away from
sharp edges, heatsinks & other
hight-temperature parts.
Legend:
Hook
WIRE DRESSING FOR REVERSE CRT MODEL
(KV-SZ292M31 only)
2-19. Lead Assy, Jumper wire dressing at A board
No. Part
No.
Description
2
WIRE UL1007 AWG24 150MM ORG
Lead Assy, Jumper
1
W082
W077
W016
W084
W065
Dress both Lead
Assy, Jumpers
around CN905,
C903 and
below Conn Assy,
5P YUV
Keep Lead Assy, Jumpers
away from R121
CN905
P/N 1-910-026-28
P/N 1-923-512-11
Conn Assy,
5P YUV
C903
C514
Dress both Lead Assy, Jumpers
along edge of shield case
Dress Lead Assy, Jumper far
away from C514 and T501.
T501
1-910-026-28
1-923-512-11
Block
A(Com)
A(Var)
Remarks
W016-W084(1)
W077-W065(0)
W082-W010(1)
1) Insert and dress Conn Assy, 4P into hook.
2) Insert Conn Assy, 5P into CN4105.
3) Dress Conn Assy, 5P; Lead Assy, Speaker and Lead Assy, Earth with pin, wire A013.
2) Insert Conn Assy, 5P into CN4105.
3) Dress Conn Assy, 5P; Lead Assy, Speaker and Lead Assy, Earth with pin, wire A013.
2.20. Wire Dressing at A and H2 board
Conn Assy, 4P
Conn Assy, 7P
Insert Conn Assy, 4P
into hook
CN4113
CN3102
CN4110
CN2105
1
CN4105
CN4106
Conn Assy, 4P
AC Power Cord is behind Lead
Assy, Speaker
Lead Assy, Speaker
Dress Conn Assy, 5P; Lead Assy,
Speaker and Lead Assy, Earth with
pin, wire A013
Conn Assy, 5P
Lead Assy, Earth
2
3
TVSR:
Connector assy must be kept away from
primary area (10mm minimum).
Connector assy must be kept away from
primary area (10mm minimum).
Click on the first or last page to see other KV-SZ292M31 (serv.man2) service manuals if exist.