Read Sony KV-SZ252M50 (serv.man3) Service Manual online
– 12 –
KV-SZ252M50/M91
RM-GA002
2-17. Dress Lead Assy, Speaker to Rotation Coil using Purse Lock
Ø
9
2-18. Dressing of PF Board Conn Assy
(for models with PF board only)
2-19. Cap Assy, High Voltage Installation
Dress Lead Assy, Speaker to center position of Rotation Coil using purse lock Ø 9 as shown. Make sure Earth
Assy, Coating wire is above Lead Assy, Speaker. This is to keep Lead Assy, Speaker away from Deflection Yoke.
Assy, Coating wire is above Lead Assy, Speaker. This is to keep Lead Assy, Speaker away from Deflection Yoke.
TVSR Requirement:
1. Keep HV cable away from conductive parts
(distance of 1mm/kV).
2. Keep spacing between edge of anode cap
& conductive parts (distance of 0.5mm/kV).
3. Keep spacing between edge of anode cap &
non-conductive parts (distance of at least 5mm or more).
1. Keep HV cable away from conductive parts
(distance of 1mm/kV).
2. Keep spacing between edge of anode cap
& conductive parts (distance of 0.5mm/kV).
3. Keep spacing between edge of anode cap &
non-conductive parts (distance of at least 5mm or more).
Keep distance of
0.5mm/kV
Keep distance of
1mm/kV
90º
>5mm
Earth Assy, Coating
wire
Dress Lead Assy, Speaker to
center position of Rotation Coil
using purse lock Ø 9
DGC Connector is below Conn Assy,
3P VH to keep Conn Assy, 3P VH
away from Heatsink A007 and D604
Keep wires away from
heatsinks A007, D604 and
conductive parts
Apply to all SZ252 Narrow 220V CISPR models ONLY
Clamp the ferrite core at the end of the DGC
wire as shown. Position it directly above DGC
Connector's housing
Purse lock Ø 9
Rotation Coil
Lead Assy, Speaker
(RED+BLK)
(RED+BLK)
Earth Assy, Coating wire is
above Lead Assy, Speaker
above Lead Assy, Speaker
Rotation coil
DGC Connector
A007
D604
DGC Band
HV Cap
Rotation coil
DGC
CN605
CN6620
Housing
Connector Assy,
3P VH
DY
Rotation Coil
Attach purse lock Ø 9
here
Lead Assy,
Speaker
Lead Assy,
Speaker
Lead Assy, Speaker
goes behind DGC
Dress Lead Assy, Speaker
directly on to DGC using
purse lock Ø 9
Pull wire to left
Lead Assy, Speaker
goes behind DGC
Pull wire to
the right
Loop Lead Assy, Speaker and
dress directly on to DGC using
purse lock
Ø 9
Click on the first or last page to see other KV-SZ252M50 (serv.man3) service manuals if exist.