– 7 –
KV-SZ252M50/M91
RM-GA002
SECTION 2
WIRE DRESSING
CAUTION :
1. Do not overpull the wires during dressing
1. Do not overpull the wires during dressing
--> avoid disconnection of wires.
2. Make sure wires are kept away from
sharp edges, heatsinks & other
high-temperature parts.
high-temperature parts.
2-1. Lead Assy, Jumper Wire Dressing at A board
2-3. Wire Dressing at A and H2 board
2-2. Lead Assy, Jumper Wire Dressing at A board
(only for Audio 6+6 Non DSP models)
TVSR:
Connector assy must be kept away
from primary area(10mm minimum).
Connector assy must be kept away
from primary area(10mm minimum).
i) Insert and dress Conn Assy, 4P into hook.
ii) Insert Conn Assy, 5P into CN4105.
Make sure AC Power Cord is behind Lead Assy,
Speaker at CN4106.
Make sure AC Power Cord is behind Lead Assy,
Speaker at CN4106.
W082
W077
P/N 1-923-512-11
W016
Dress both Lead Assy, Jumpers
along edge of shield case
P/N 1-910-026-28
Conn Assy,
5P YUV
CN905
Dress both Lead
Assy, Jumpers
around CN905, C903
and below Conn
Assy, 5P YUV
C903
Dress Lead Assy, Jumper far
away from C514 and T501
W010
W065
W084
C514
T501
Keep Lead Assy, Jumpers
away from R121
No. Part
No.
Description
Block
Remark
1 1-910-026-28
Lead
Assy,
Jumper
A(Var)
W016-W084(1)
W077-W065(0)
2
1-923-512-11 WIRE UL1007 AWG24 150MM ORG
A(Com) W082-W010(1)
No. Part
No.
Description
Block
Remark
2 1-910-036-25
Lead
Assy,
Jumper
A(Var) W075-W085(1)
2
1
CN4113
CN3102
CN2105
CN4110
Conn Assy, 4P
CN4106
CN4105
Lead Assy, Speaker
Conn Assy, 5P
AC Power Cord is behind
Lear Assy, Speaker
Conn Assy, 7P
Insert Conn Assy,
4P into hook
W075
P/N 1-910-036-25
L2601
A003
A002
W085
Dress Lead Assy,
Jumper around C249
Dress Lead Assy, Jumper in
between C211 and L2601
C211
UL Tube
Dress between
A003 and A002