KV-SZ252M50 (serv.man3) - Sony TV Service Manual (repair manual). Page 14

Read Sony KV-SZ252M50 (serv.man3) Service Manual online

– 13 –
KV-SZ252M50/M91
RM-GA002
2-20.  HV Cap Assy Wire Dressing
2-21.  AC Power Cord Wire Dressing
Dress Cap Assy, High Voltage with Holder, HV Cable combi as shown.
CAUTION: 1) Make sure the specified position is 
 
being followed.
                  2)  Position the Cap Assy, High Voltage in 
 
the inner ring of the Holder, HV cable  
 
combi (see diagram).
TVSR requirement:
1. Spacing between HV cable and other conductive
part's surface is 1mm/kV or more.
2. Spacing between HV cable's and enclosure with
ventilation or the edge where terminal bracket and  
rear cover meet: 10mm or more.
Install AC cord holder to AC power cord at specified position as shown.
290 ± 5mm 
630 ± 5mm 
Hook AC cord into
CRT support's hook
Make sure AC cord is
straight between 
boss and holder
Attach AC cord onto
holder and insert to
bottom cover
Attach Purse Lock (S)
Ø 8 in to rear cover
Holder, HV cable combi
250 ± 5 mm
Large hook
Top view
Rotation coil
DGC
Dress behind boss
AC Cord Holder
Inner Ring
90º
CRT's carbon
area
HV cap
10 o'clock position
purse lock 
Ø
 9.
Dress Holder, HV Cable Combi to Cap Assy,
High Voltage and attach side hook to rotation
coil at 10 o'clock position. Then, attach large
hook to DGC and dress with
purse lock 
Ø
 9.
DGC
Side hook
Large 
hook
P-P taping
of DGC
Dress using Purse lock 
Ø
 9
Dress Holder, HV Cable
Combi to the right of P-P
taping of DGC. Dress
purse lock 
Ø
 9 to the right
of large hook on Holder,
HV Cable Combi.
CRT's carbon
area
Min. distance = 1mm/kV
Min. distance = 1mm/kV
Keep distance of HV cable
from other wires, conductive
parts and CRT's carbon area
Purse lock 
Ø
 9
Side hook
Page of 72
Display

Click on the first or last page to see other KV-SZ252M50 (serv.man3) service manuals if exist.