Read Sony KV-SZ252M50 (serv.man3) Service Manual online
– 13 –
KV-SZ252M50/M91
RM-GA002
2-20. HV Cap Assy Wire Dressing
2-21. AC Power Cord Wire Dressing
Dress Cap Assy, High Voltage with Holder, HV Cable combi as shown.
CAUTION: 1) Make sure the specified position is
being followed.
2) Position the Cap Assy, High Voltage in
the inner ring of the Holder, HV cable
combi (see diagram).
TVSR requirement:
1. Spacing between HV cable and other conductive
part's surface is 1mm/kV or more.
2. Spacing between HV cable's and enclosure with
ventilation or the edge where terminal bracket and
rear cover meet: 10mm or more.
1. Spacing between HV cable and other conductive
part's surface is 1mm/kV or more.
2. Spacing between HV cable's and enclosure with
ventilation or the edge where terminal bracket and
rear cover meet: 10mm or more.
Install AC cord holder to AC power cord at specified position as shown.
290 ± 5mm
630 ± 5mm
Hook AC cord into
CRT support's hook
Make sure AC cord is
straight between
boss and holder
Attach AC cord onto
holder and insert to
bottom cover
Attach Purse Lock (S)
Ø 8 in to rear cover
Holder, HV cable combi
250 ± 5 mm
Large hook
Top view
Rotation coil
DGC
Dress behind boss
AC Cord Holder
Inner Ring
90º
CRT's carbon
area
HV cap
10 o'clock position
purse lock
Ø
9.
Dress Holder, HV Cable Combi to Cap Assy,
High Voltage and attach side hook to rotation
coil at 10 o'clock position. Then, attach large
hook to DGC and dress with
purse lock
Ø
9.
DGC
Side hook
Large
hook
P-P taping
of DGC
Dress using Purse lock
Ø
9
Dress Holder, HV Cable
Combi to the right of P-P
taping of DGC. Dress
purse lock
Ø
9 to the right
of large hook on Holder,
HV Cable Combi.
CRT's carbon
area
Min. distance = 1mm/kV
Min. distance = 1mm/kV
Keep distance of HV cable
from other wires, conductive
parts and CRT's carbon area
Purse lock
Ø
9
Side hook