Read Sony KV-HP213M83 Service Manual online
– 13 –
KV-HP213N63,N63/S,M83
RM-GA002
2-10. AC Power Cord and Front Control wire dressing
Front Control wire
H3 board
Wire is placed
behind DGC
behind DGC
CAUTION : during Bottom Cover docking
Front Control wire possible to get trap at
edge where beznet and bottom cover meet.
1) To prevent this, temporary place wire
behind
edge where beznet and bottom cover meet.
1) To prevent this, temporary place wire
behind
DGC.
2) Take out wire for final dressing shown in
Figure
Figure
12(c).
For Illustration only
Make sure Front Control wire lie flat on bottom cover
and dressed around AC Power Cord as shown.
=> Keep wire away from nearby heatsink.
and dressed around AC Power Cord as shown.
=> Keep wire away from nearby heatsink.
Front Control wire
Bottom Cover
AC Power Cord
Insert AC Power Cord into
CRT support's hook
CRT support's hook
Keep power cord away from heatsink
CRT Support
2-11. DY Connector Dressing
Use heatsink height to
estimate purse lock location
TVSR (Clause 9.4.7):
All wires must be kept away from FBT
area by a distance of 10mm or more.
All wires must be kept away from FBT
area by a distance of 10mm or more.
Purse
Lock Ø5
DY Connector
Conn Assy, 5P
(200V)
1) DY Connector goes underneath
of Earth Assy, Coating and
Connector Assy, 5P (200V) wire.
of Earth Assy, Coating and
Connector Assy, 5P (200V) wire.
2) DY Connector goes above
Connector Assy, 5P (200V) wire.
Connector Assy, 5P (200V) wire.
DY Connector
Conn Assy, 5P (200V)
Earth Assy, Coating
Purse Lock Ø5
Dress wires
away from FBT
3) Dress DY Connector and
Connector Assy, 5P (200V)
wire with Purse Lock Ø5.
Connector Assy, 5P (200V)
wire with Purse Lock Ø5.
Make sure DY Connector is on the
right side of Earth Assy, Coating
right side of Earth Assy, Coating
2
3
1