HDR-PJ260, HDR-PJ260E, HDR-PJ260V, HDR-PJ260VE, HDR-XR260V, HDR-XR260VE - Sony Movie Service Manual (repair manual). Page 7

Read Sony HDR-PJ260 / HDR-PJ260E / HDR-PJ260V / HDR-PJ260VE / HDR-XR260V / HDR-XR260VE Service Manual online

1-4
HDR-PJ260/PJ260E/PJ260V/PJ260VE/XR260E/XR260V/XR260VE_L2
1-6.
 SELF-DIAGNOSIS FUNCTION
1-6
-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis 
function starts working, and displays on the LCD screen what to do.
This function consists of two display; self-diagnosis display and service 
mode display.Details of the self-diagnosis functions are provided in the 
Instruction manual.
1-6
-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the LCD 
screen shows a 4-digit display consisting of an alphabet and numbers,
which blinks at 3.2 Hz. This 5-character display indicates the “repaired 
by:”, “block” in which the problem occurred, and “detailed code”of the 
problem.
0 0
3 2
C
Repaired by:
Refer to “1-6-3. Self-diagnosis Code Tabl e”.
Indicates the appropriate
step to be taken.
E.g.
13 ....
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
E : Corrected by service
engineer
Format the “memory card”.
LCD screen
1-5.
  PRECAUTION ON REPLACING THE LENS
When replacing the lens, write down the PITCH/YAW data given on the data sheet of the replacement lens for service.
Start the Adjust Manual in the Adjust Station and execute the “GYRO sensor sensitivity Adj”.
PITCH data
YAW data
P.PP/Y.YY
L2
L1
P.PP/Y.YY
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1 2012.01
1-6
-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or place it in a cool place.
C
1
3
0
Memory card is unformatted.
Memory card is broken.
Format the memory card.
Insert a new memory card.
C
1
3
0
2
Access error
Remove the power source. Reconnect it again and operate your cam-
corder again.
C
1
3
0
3
Access error (External media)
Turn power off and turn power on again.
C
1
3
0
4
Drive fault (External media)
Turn power off and turn power on again.
C
E
3
2
6
1
6
0
0
0
Difficult to adjust focus
(Cannot initialize focus)
Retry turn the power on by the power switch. If it does not recover, check 
the focus sensor of lens block (pin 7 of CN4002 on the LD-279 board). 
If it is OK, check the focus motor drive IC (IC5501 on the VC-653 board).
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note 1)
E
3
1
0
0
Drive fault
Turn power off and turn power on again.
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the lens block zoom sensor signal (pin 9 of CN4002 on the LD-
279 board) when zooming is performed when the zoom lever is operated, 
and the zoom motor drive circuit (IC5501 on the VC-653 board) when 
zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of 
the focus lens and the abnormalities in 
initialization of the zoom lens occurred 
simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the step-
per iris initializing
Turn the power on to open lens barrier. Disconnect the battery or power 
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens drive 
block (CN4002 pin qj, qk on LD-279 board).
If iris blades work normally, confirm that they are closing completely 
and confirm following item.
・  Case of the iris blades do not close normally Replace the lens block).
・  Case of “E: 61: 30” is appeared and iris blades closed completely.
  Confirm that communication with lens block is normal.
・  Case of LCD is not displayed normally Check that connection between 
CN6702 on CM-123 board and CN4002 on VC-653 board by FP-1488 
flexible board.
・  Case of LCD is displayed normally Replace the lens block.
E
6
2
0
0
Handshake correction function does not 
work well. (With PITCH angular velocity 
sensor output stopped.)
Inspect PITCH angular velocity sensors (SE7501 on the MS-478 board) 
peripheral circuits.
E
6
2
0
1
Handshake correction function does not 
work well. (With YAW angular velocity 
sensor output stopped.)
Inspect YAW angular velocity sensors (SE7501 on the MS-478 board) 
peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to [
1-7
-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Occurred].
E
6
2
0
3
IC for steadyshot and micro controller 
communication abnormality among.
Inspect the steadyshot circuit (IC5501 on the VC-653 board).
E
6
2
0
4
Image vibration correction during
handshake function does not work.
Inspect the image vibration angular velocity sensors (SE7701 on the 
LD-279 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block. (Note 3) If an error occurs again, replace 
the VC-653 board.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to [
1-7
-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred].
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to [
1-7
-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred].
Note 1: Start the Adjust Manual in the Adjust Station and refer to the “DESTINATION DATA WRITE”.
Note 2: Functions of codes with * mark are not provided in this unit.
*
*
*
(                                           )
Page of 28
Display

Click on the first or last page to see other HDR-PJ260 / HDR-PJ260E / HDR-PJ260V / HDR-PJ260VE / HDR-XR260V / HDR-XR260VE service manuals if exist.