HDR-FX1, HDR-FX1E (serv.man9) - Sony Movie Service Manual (repair manual). Page 10

Read Sony HDR-FX1 / HDR-FX1E (serv.man9) Service Manual online

— 10 —
HDR-FX1/FX1E
Added contents
Page 6-12
5-4. 13 Page Table (Mechanism Control Microprocessor
Version 6.0 (MP6) to Version 8.0 (MP8))
Note1: When reading or writing the 13 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 13 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
13, 18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
13, 18, 1C Page Data”).
Note3: When the mechanism control microprocessor is replaced, check
that the data of the fixed data address shown in the table is the
initial value. If not, change the data to the initial value.
Refer to “1. Initialization of 8, C, 13, 18, 1C page data” for the
version check of the mechanism control microprocessor.
Table. 6-1-8 (4).
Address
Remark
Initial value
Address
Remark
Initial value
00 to 03
04
05
06
07
08
09
0A
0B
0C to 12
13
14 to 24
25
26 to 89
8A
8B
8C to B6
B7
B8
B9
BA to BD
BE
BF to D5
08
00
46
01
02
00
00
00
55
61
0C
60
60 or 78
00 or 01
Serial No. input
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data (Note3)
60: Mechanism control microprocessor
Ver. 6.0 (MP6)
78: Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
Fixed data-1
Fixed data (Note3)
00: Mechanism control microprocessor
Ver. 6.0 (MP6) or Ver. 7.0 (MP7)
01: Mechanism control microprocessor
Ver. 8.0 (MP8)
Fixed data-1
Address
Remark
Initial value
Address
Remark
Initial value
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF to E8
E9
EA to ED
EE
EF to FF
00 or 3C
00 or 0A
00 or 3C
00 or 1E
1E or 1D
11 or 15
1E
1E
81
80
Fixed data (Note3)
00: Mechanism control microprocessor
Ver. 6.0 (MP6) or Ver. 7.0 (MP7)
3C: Mechanism control microprocessor
Ver. 8.0 (MP8)
Fixed data (Note3)
00: Mechanism control microprocessor
Ver. 6.0 (MP6)
0A:Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
Fixed data (Note3)
00: Mechanism control microprocessor
Ver. 6.0 (MP6)
3C: Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
Fixed data (Note3)
00: Mechanism control microprocessor
Ver. 6.0 (MP6)
1E: Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
Fixed data-1
Fixed data (Note3)
1E: Mechanism control microprocessor
Ver. 6.0 (MP6)
1D:Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
Fixed data (Note3)
11: Mechanism control microprocessor
Ver. 6.0 (MP6)
15: Mechanism control microprocessor
Ver. 7.0 (MP7) or Ver. 8.0 (MP8)
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
Page of 25
Display

Click on the first or last page to see other HDR-FX1 / HDR-FX1E (serv.man9) service manuals if exist.