— 11 —
HDR-FX1/FX1E
Before change
After change
Page 6-12
6. 18 Page Table
Note1: When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
13, 18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
13, 18, 1C Page Data”).
Table. 6-1-9.
Address
00 to 5D
5E
5F to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
6. 18 Page Table
6-1. 18 Page Table (Mechanism Control Microprocessor
Version 1.0 (MP1) to Version 2.0 (MP2))
Note1: When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
13, 18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
13, 18, 1C Page Data”).
Address
00 to 38
39
3A
3B
3C
3D to 5D
5E
5F
60
61
62
63 to FF
Remark
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Table. 6-1-9 (1).
Added contents
Page 6-12
6-2. 18 Page Table (Mechanism Control Microprocessor
Version 3.0 (MP3) to Version 8.0 (MP8))
Note1: When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
13, 18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
13, 18, 1C Page Data”).
Note3: When the mechanism control microprocessor is replaced, check
that the data of the fixed data address shown in the table is the
initial value. If not, change the data to the initial value.
Address
Remark
Initial value
Address
Remark
Initial value
00 to 07
08
09
0A
0B
0C
0D to 76
77
78
79 to 7A
7B
7C
79 to FF
96
36
30
38
58
01
40
03
40
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
Fixed data (Note3)
Fixed data-1
Table. 6-1-9 (2).
 : Changed portion   
 : Added portion
Page of 25
Display