HDR-CX130, HDR-CX130E, HDR-CX160, HDR-CX160E, HDR-CX180, HDR-CX180E (serv.man2) - Sony Movie Service Manual (repair manual). Page 7

Read Sony HDR-CX130 / HDR-CX130E / HDR-CX160 / HDR-CX160E / HDR-CX180 / HDR-CX180E (serv.man2) Service Manual online

HDR-CX130/CX130E/CX160/CX160E/CX180/CX180E_L2
1-3
1-5-2. E : 62 : 11 [Shift Lens Overheating (Pitch)] Occurred
Order
AdjustBlock
AdjustCode
Order
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the [SERVICE] 
tab.
2
Check if the shift lens moves while setting the order 1.
If the shift lens does not move, replace the lens block (Note).
When the shift lens moved, proceed to the order 3.
3
While setting the order 1, measure with an oscilloscope the output voltage of C5526 and C5527 in the 
periphery of IC5501 on the VC-617 board to check the output voltage varies.
4
If the output voltage does not vary, replace the lens block (Note).
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
6
While measuring with an oscilloscope the output voltage of C5506 in the periphery of IC5501 on the 
VC-617 board, turn the power ON to check that the output voltage immediately after the power on 
change as shown in Fig. 2.
7
If the output voltage change as shown in Fig. 2, replace the lens block(Note).
If it does not change as shown in Fig. 2, inspect the camera control circuit (IC1301 and IC5501 of VC-
617 board) periphery.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
 
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.  
 
1-5-3. E : 62 : 12 [Shift Lens Overheating (Yaw)] Occurred
Order
AdjustBlock
AdjustCode
Order
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the [SERVICE] 
tab.
2
Check if the shift lens moves while setting the order 1.
If the shift lens does not move, replace the lens block (Note).
When the shift lens moved, proceed to the order 3."
3
While setting the order 1, measure with an oscilloscope the output voltage of C5528 and C5529 in the 
periphery of IC5501 on the VC-617 board to check the output voltage varies.
4
If the output voltage does not vary, replace the lens block (Note).
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
6
While measuring with an oscilloscope the output voltage of C5506 in the periphery of IC5501 on the 
VC-617 board, turn the power ON to check that the output voltage immediately after the power on 
change as shown in Fig. 2.
7
If the output voltage change as shown in Fig. 2, replace the lens block(Note).
If it does not change as shown in Fig. 2, inspect the camera control circuit (IC1301 and IC5501 of VC-
617 board) periphery.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.   
 
 
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-5-4. E : 62 : 20 [Abnormality of Thermistor] Occurred
Order
Procedure
1
Turn the power ON.
2
Confirm the connections of flexible flat cables and connectors between the lens block and VC-617 board.
3
In case of no malfunction of connections, replace the lens block with new one (Note) . When the error has occurred in spite of the lens 
replacement, replace VC-617 board with new one.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
– ENGLISH –
– JAPANESE –
1-1.  修理時の電源供給について
本機では,安定化電源(8.4Vdc)からバッテリ端子に電源を供給した場合,約10秒後にシャットオフし,動作しなくなります。
これを避けるため,下記の方法を用いてください。
方法:
ACアダプタを使用する。
1-2.  VC-617基板交換時の注意
基板交換時は,下記の点に注意してください。
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を実行させてください。
補修用基板交換後、電源を入れると内蔵記録メディアエラーが表示される場合がありますが、「DESTINATION  DATA  WRITE」を実行
させると消えます。「DESTINATION DATA WRITE」実行しても消えない場合は、内蔵記録メディアをフォーマットしてください。
USBシリアルセーブ
補修用基板と交換する時,交換前の基板よりUSBシリアルNo.を取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「USB SERIAL SAVE」を実行させてください。
USBシリアルNo.
セットは,1台毎に異なる固有のID(USB Serial No.)を書き込んだ後,出荷されています。
新品の補修用基板には,このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
Adjust StationからAdjust Manualを起動させて「USB SERIAL No. INPUT」を実行させてください。
1-3.  MM-098基板交換時の注意
角速度センサ
補修用基板と交換する時,角速度センサSE7501 (PITCH/YAW) の感度表示を書き留めてください。
Adjust StationからAdjust Manualを起動させて「GYRO sensor sensitivity adj.」を実行させてくだ
SE7501
MM-098 BOARD (SIDE B)
YY
PP
G1
G2
PP:
PITCH 感度表示 
YY:
YAW 感度表示 
Note:MM-098基板のSE7501 (PITCH/YAW) 感度表示は補修用基板にのみ記載されています。
The changed portions from
Ver. 1.1 are shown in blue.
Ver. 1.2 2011.08
Page of 20
Display