Read Sony HDR-CX130 / HDR-CX130E / HDR-CX160 / HDR-CX160E / HDR-CX180 / HDR-CX180E (serv.man2) Service Manual online
HDR-CX130/CX130E/CX160/CX160E/CX180/CX180E_L2
1-2
– ENGLISH –
1-5. METHOD OF COPING WITH SHIFT LENS ERROR
VC-617 BOARD (SIDE B)
VC-617 BOARD (SIDE A)
IC1301
C5506
IC5501
C5526
C5527
C5529
C5528
Fig. 1
Measurement points on the VC-617 board
about 330 msec
Note: The length of low section will vary a little depending on the conditions.
Fig. 2
Change in output voltage of C5506 on the VC-617 board
1-5-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of C5506 in the periphery of IC5501 on the VC-617 board, turn the
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect
the camera control circuit (IC1301 of VC-617 board) periphery.
the camera control circuit (IC1301 of VC-617 board) periphery.
Note: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
0
0
Difficult to adjust focus.
(Cannot initialize focus.)
(Cannot initialize focus.)
Inspect the lens block focus reset sensor (pin 7 of CN1003 on the
VC-617 board) when focusing is performed when the focus buttons are
pressed in the focus manual mode, and the focus motor drive circuit
(IC5501 on the VC-617 board) when the focusing is not performed.
VC-617 board) when focusing is performed when the focus buttons are
pressed in the focus manual mode, and the focus motor drive circuit
(IC5501 on the VC-617 board) when the focusing is not performed.
E
6
1
1
0
Zoom operations fault.
(Cannot initialize zoom lens.)
(Cannot initialize zoom lens.)
Inspect the lens block zoom reset signal (pin 9 of CN1003 on the
VC-617 board) when zooming is performed when the zoom lever is
operated, and the zoom motor drive circuit (IC1301 on the VC-617
board) when zooming is not performed.
VC-617 board) when zooming is performed when the zoom lever is
operated, and the zoom motor drive circuit (IC1301 on the VC-617
board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of the focus
lens and the abnormalities in initialization of
the zoom lens occurred simultaneously.
lens and the abnormalities in initialization of
the zoom lens occurred simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the stepper
iris initializing.
iris initializing.
Turn power off and turn power on again.
E
6
2
0
0
Handshake correction function does not work
well. (With PITCH angular velocity sensor
output stopped.)
well. (With PITCH angular velocity sensor
output stopped.)
Inspect PITCH angular velocity sensors (SE7501 on the MM-098
board) peripheral circuits.
board) peripheral circuits.
E
6
2
0
1
Handshake correction function does not work
well. (With YAW angular velocity sensor
output stopped.)
well. (With YAW angular velocity sensor
output stopped.)
Inspect YAW angular velocity sensors (SE7501 on the MM-098
board) peripheral circuits.
board) peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to [1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred].
curred].
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
munication abnormality among.
Inspect the steadyshot circuit (IC5501 on the VC-617 board).
E
6
2
0
4
Image vibration correction during
handshake function does not work.
handshake function does not work.
Inspect the image vibration angular velocity sensors (SE7501 on
the MM-098 board) peripheral circuits.
the MM-098 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block. (Note 3) If an error occurs again, replace
the VC-617 board.
the VC-617 board.
E
6
2
1
1
Shift lens overheating (Pitch).
Refer to [1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Oc-
curred].
curred].
E
6
2
1
2
Shift lens overheating (Yaw).
Refer to [1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Oc-
curred].
curred].
E
6
2
2
0
Abnormality of thermistor.
Refer to [1-5-4. E : 62 : 20 (Abnormality of Thermistor) Occurred].
E
9
1
0
1
Abnormality when flash is beingcharged.
Checking of flash unit or replacement of flash unit.
E
9
1
0
2
Abnormality of LED Video light.
Turn power off and turn power on again.
E
9
1
0
3
Abnormality of LED Video light Tempera-
ture detection.
ture detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max
discharge current.
discharge current.
Check the remaining battery power because this symptom maybe
depended on the remaining battery level, and confirm whether
or not the symptom is occurred after replacing the battery. If the
symptom is still occurred, overhaul inspection is needed. Check
each output of DC/DC converter (IC4301) on VC-617 board with
connected the DC JACK (J901).
(The minimum connection to periphery)
depended on the remaining battery level, and confirm whether
or not the symptom is occurred after replacing the battery. If the
symptom is still occurred, overhaul inspection is needed. Check
each output of DC/DC converter (IC4301) on VC-617 board with
connected the DC JACK (J901).
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing the flash mem-
ory.
ory.
Inspect the flash memory (IC8101 on the MM-098 board).
E
9
4
0
1
Internal flash memory fault.
Inspect the flash memory (IC8101 on the MM-098 board).
E
9
4
0
2
BGM data error.
Inspect the flash memory (IC8101 on the MM-098 board). If it is
OK, check the CPU (IC1301 on the VC-617 board).
OK, check the CPU (IC1301 on the VC-617 board).
E
9
5
0
0
GPS hardware error.
Turn power off and turn power on again.
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
9
6
0
0
Map area mount error.
Turn power off and turn power on again.
E
9
7
0
0
Projector hardware error.
Turn power off and turn power on again.
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
*
*
*
*
*
*
Click on the first or last page to see other HDR-CX130 / HDR-CX130E / HDR-CX160 / HDR-CX160E / HDR-CX180 / HDR-CX180E (serv.man2) service manuals if exist.