1-5.  METHOD OF COPING WITH SHIFT LENS ERROR
VC-617 BOARD (SIDE B)
VC-617 BOARD (SIDE A)
IC1301
C5506
IC5501
C5526
C5527
C5529
C5528
Fig. 1
Measurement points on the VC-617 board
about 330 msec
Note: The length of low section will vary a little depending on the conditions.
Fig. 2
Change in output voltage of C5506 on the VC-617 board
1-5-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of C5506 in the periphery of IC5501 on the VC-617 board, turn the 
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect 
the camera control circuit (IC1301 of VC-617 board) periphery.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
0
0
Difficult to adjust focus.
(Cannot initialize focus.)
Inspect the lens block focus reset sensor (pin 7 of CN1003 on the 
VC-617 board) when focusing is performed when the focus buttons are 
pressed in the focus manual mode, and the focus motor drive circuit 
(IC5501 on the VC-617 board) when the focusing is not performed.
E
6
1
1
0
Zoom operations fault.
(Cannot initialize zoom lens.)
Inspect the lens block zoom reset signal (pin 9 of CN1003 on the 
VC-617 board) when zooming is performed when the zoom lever is 
operated, and the zoom motor drive circuit (IC1301 on the VC-617 
board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing.
Turn power off and turn power on again.
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Inspect PITCH angular velocity sensors (SE7501 on the MM-098 
board) peripheral circuits.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Inspect YAW angular velocity sensors (SE7501 on the MM-098 
board) peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to [1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred].
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Inspect the steadyshot circuit (IC5501 on the VC-617 board).
E
6
2
0
4
Image vibration correction during
handshake function does not work.
Inspect the image vibration angular velocity sensors (SE7501 on 
the MM-098 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block. (Note 3) If an error occurs again, replace 
the VC-617 board.
E
6
2
1
1
Shift lens overheating (Pitch).
Refer to [1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Oc-
curred].
E
6
2
1
2
Shift lens overheating (Yaw).
Refer to [1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Oc-
curred].
E
6
2
2
0
Abnormality of thermistor.
Refer to [1-5-4. E : 62 : 20 (Abnormality of Thermistor) Occurred].
E
9
1
0
1
Abnormality when flash is beingcharged.
Checking of flash unit or replacement of flash unit.
E
9
1
0
2
Abnormality of LED Video light.
Turn power off and turn power on again.
E
9
1
0
3
Abnormality of LED Video light  Tempera-
ture detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max 
discharge current.
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether 
or not the symptom is occurred after replacing the battery. If the 
symptom is still occurred, overhaul inspection is needed. Check 
each output of DC/DC converter (IC4301) on VC-617 board with 
connected the DC JACK (J901). 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing the flash mem-
ory.
Inspect the flash memory (IC8101 on the MM-098 board).
E
9
4
0
1
Internal flash memory fault.
Inspect the flash memory (IC8101 on the MM-098 board).
E
9
4
0
2
BGM data error.
Inspect the flash memory (IC8101 on the MM-098 board). If it is 
OK, check the CPU (IC1301 on the VC-617 board).
E
9
5
0
0
GPS hardware error.
Turn power off and turn power on again.
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
9
6
0
0
Map area mount error.
Turn power off and turn power on again.
E
9
7
0
0
Projector  hardware error.
Turn power off and turn power on again.
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
*
*
*
*
*
*
Page of 20
Display

Click on the first or last page to see other HDR-CX130 / HDR-CX130E / HDR-CX160 / HDR-CX160E / HDR-CX180 / HDR-CX180E (serv.man2) service manuals if exist.