DCR-SR30E, DCR-SR40, DCR-SR40E (serv.man4) - Sony Movie Service Manual (repair manual). Page 11

Read Sony DCR-SR30E / DCR-SR40 / DCR-SR40E (serv.man4) Service Manual online

6-9
DCR-SR30E/SR40/SR40E_ADJ
2.
Modification of 9, A, B, D, 13, 15, 17, 1A, 1B Page
Data
If the 9, A, B, D, 13, 15, 17, 1A, 1B page data has been initialized,
change the data of the “Fixed data-2” address shown in the fol-
lowing table by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 9, A, B, D, set data: 00 to
page: 0, address: 10, and then select pages 9, A, B, D.
3) If modification of data on pages 13, 15, 17, 1A, 1B, set data:
01 to page: 0, address: 10, and then select pages 3, 5, 7, A, B.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification 9, A, B, D, 13, 15,
17, 1A, 1B page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
Note 2:
This operation should be done with the adjustment re-
mote commander. The operation of page: 02 cannot be
performed with the SeusCam.
Note 3:
If following symptoms occur after completing of the
“Modification 9, A, B, D, 13, 15, 17, 1A, 1B page data”,
check that the data of the “Fixed data-2” address of 9, A,
B, D, 13, 15, 17, 1A, 1B page are same as those of same
model of same destination.
1) The power is shut off so that unit cannot operate.
3.
9 Page table
Note 1:
Check that the data of page: 0, address: 10 is“00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
Page of 54
Display

Click on the first or last page to see other DCR-SR30E / DCR-SR40 / DCR-SR40E (serv.man4) service manuals if exist.