Read Sony BDP-CX960 Service Manual online
BDP-CX960
23
2. ERROR CODE LIST
Major category
Category code
Details of cause
and error contents
Display
on FL
tube
Error information displayed in error
log
Corrective action at service
center
Category
err_code
err_info
(4byte length)
ERRLOG_
CATEGORY_
THERMO
Shutdown due to
temperature rise of
the set
FAN ERR
0x05
0x01
Check the ambient temperature of
the set
the set
FAN is defective
FAN ERR
0x02
Replace the fan
ERRLOG_
CATEGORY_
NVRAM
NAND Error
E7001
0x07
0x01
Reboot the set, and if the error
recurs or if the set malfunctions,
perform the service. (When the error
persists though NVRAM is forcibly
initialized, replace the NAND. All the
data in NVRAM including the setting
information are initialized)
recurs or if the set malfunctions,
perform the service. (When the error
persists though NVRAM is forcibly
initialized, replace the NAND. All the
data in NVRAM including the setting
information are initialized)
E7002
0x02
E7003
0x03
E7004
0x04
E7005
0x05
Reboot the set for automatic recov-
ery. If the error recurs, perform the
service. (When the error persists
though NVRAM is forcibly initialized,
replace the NAND. All the data in
NVRAM including the setting infor-
mation are initialized)
ery. If the error recurs, perform the
service. (When the error persists
though NVRAM is forcibly initialized,
replace the NAND. All the data in
NVRAM including the setting infor-
mation are initialized)
E7006
0x06
E7007
0x07
E7008
0x08
E7009
0x09
E7010
0x0A
E7011
0x0B
NAND
(SdmRegistry)
Error
E7101
0x65
Reboot the set and if the error oc-
curs, perform the service. (Replace
the NAND because it reached the
life)
curs, perform the service. (Replace
the NAND because it reached the
life)
E7102
0x66
E7103
0x67
E7104
0x68
E7105
0x69
N/A
NAND (Database)
Error
E9101
No error log is recorded.
Reboot the set, and if the error
recurs, perform the service. (When
the error persists though the “Fac-
tory Initialize” is done, replace the
NAND. All the data including setting
information are initialized)
recurs, perform the service. (When
the error persists though the “Fac-
tory Initialize” is done, replace the
NAND. All the data including setting
information are initialized)
E9102
E9103
E9104
ERRLOG_
CATEGORY_
MECHA
Mechanism
error that cannot be
specifi ed
E8000
0x09
0x00
Mechanical error. Check the each
motion and perform the service.
motion and perform the service.
Fails the door
close in initializing
mechanism
E8001
0x01
Check the door mechanism. (Gear
alignment, switch condition, Assem-
bly of the door guide rail)
alignment, switch condition, Assem-
bly of the door guide rail)
Makes an error
while the table is
operating
E8002
0x02
Check the sensor alignment. (espe-
cially the table sensor alignment)/
Check the table mechanism. (As-
sembly of gears, teeth of Table (400)
for sensor)
cially the table sensor alignment)/
Check the table mechanism. (As-
sembly of gears, teeth of Table (400)
for sensor)
Makes an error
while the loading is
operating
E8003
0x03
Check the loading mechanism and
perform the service.
perform the service.
Makes an error
while Popper is
while Popper is
operating
E8004
0x04
Check the pop-up mechanism.
(especially POP-UP lever alignment)
And check the door mechanism.
(Pop-Up is common mechanism with
door’s)
(especially POP-UP lever alignment)
And check the door mechanism.
(Pop-Up is common mechanism with
door’s)
N/A
Drive Tray Error
E8902
No error log is recorded.
Reboot the set, and if the error
recurs, perform the service. (Check
optical drive)
recurs, perform the service. (Check
optical drive)
Click on the first or last page to see other BDP-CX960 service manuals if exist.