1-5.  METHOD FOR CHECKING THE AS SLIDER UNIT
Make sure to confirm below before replacing the AS Slider B Assy.
(1)  Remove the CV Rear Cover Assy, and temporally mount the AS Slider Unit.
(2)  Set the AS Slider Unit upwards as shown in figure, and put it on a stable place.
 
(3)  Select “Slider Unit Check” of the adjustment software, and then confirm the movement to the directions of Pitch and Yaw, and if an error occurs,
 
replace it with the component part corresponding to the movement.
 
– ENGLISH –
1-4.  PRECAUTION FOR REPLACEMENT OF IMAGER
In this model, the following procedure is required when the imager is replaced.
  In the case that the imager data can be extracted from the set before the replacement, refer to “Imager DRA Data” in “1-3. PRECAUTION ON
 REPLACING 
THE 
AM-031 
BOARD”.
  In the case that the imager data cannot be extracted from the set before the replacement, replace both AM board and imager unit.
  Capture the data to PC from CD-ROM supplied with the imager unit when it is ordered.
  Write the captured data in the set using “Imager DRA Data Input” in the ADJUST tab of the Adjust manual.
  After all adjustment items have been completed, execute “Assist Check” on the SERVICE tab of the Adjust manual.
1-6.  METHOD FOR ADJUSTING THE TEBURE REVISE
Make sure to confirm below after replacing the AS Slider B Assy.
(1)  Remove the CV Rear Cover Assy, temporally mount the AS Slider Unit mounted with the Imager Sensor, and then set up the camera 
 
body and hold the AS Slider Unit as shown in figure.
 
(2)  Select “Slider Unit Check” of the adjustment software, and then confirm if the result is OK.
(3)  Select “Tebure Revise Adj.” of the adjustment software, and then confirm if the result is OK.
(4)  Mount the AS Slider Unit to the camera.
 