Read Sony SAL70200G2 Service Manual online
5-19
SAL70200G2 (2.8/70-200 G SSM Ⅱ) (70-200mm F2.8 G SSM II)
5-10. FINISHED ADJUSTMENT/INSPECTION
1. Preparation
1) Attach the lens to the equipment. (Refer to 5-7-2. Connection of Finished Inspection JIG II and Startup of Lens Adjustment Program
1) Attach the lens to the equipment. (Refer to 5-7-2. Connection of Finished Inspection JIG II and Startup of Lens Adjustment Program
(ActuatorCheckerSSM) .)
2) Start up the lens adjustment program (ACSSM-S-VerX.XX.exe).
3) Click [Setup] and perform the initial setting. (Refer to 5-7-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM) .)
3) Click [Setup] and perform the initial setting. (Refer to 5-7-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM) .)
Note:
When the Multi Serial window opens, take the following actions.
Process No.: You need not enter process number.
Serial No.: When the mount block assy is replaced, enter a serial number.
Fig.
5-10-1
2. Adjustment/Inspection procedure
1) Click [Start[Ent]] on the main screen.
1) Click [Start[Ent]] on the main screen.
Fig.
5-10-2
2) Carry out operations below following instructions on windows.
3. Adjustment/Inspection Item
1) LVDD1 Consumption Current
2) Adjust Zoom Brush
3) Zoom
1) LVDD1 Consumption Current
2) Adjust Zoom Brush
3) Zoom
Pattern
4) Focus Pattern (Motor)
5) Adjust & Check MR
6) Adjust Driving Frequency & Gain
7) Zoom Hold Button
8) AF/MF
5) Adjust & Check MR
6) Adjust Driving Frequency & Gain
7) Zoom Hold Button
8) AF/MF
Switch
9) DMF
Switch
10) Range Limit Switch
11) Focus Drive
11) Focus Drive
12) Write
⊿
SB
13) Write
⊿
SB(x1.4 TeleConverter)
14) Write
⊿
SB(x2 TeleConverter)
15)
⊿
SB is Initialized.
16)
⊿
SB is Initialized.(x1.4 TeleConverter)
17)
⊿
SB is Initialized.(x2 TeleConverter)
18) Check Sounds
19) Search Zoom-Adj
20) Search Focus-Adj
19) Search Zoom-Adj
20) Search Focus-Adj
Note:
Nine items of 12 to 20 are not executed automatically if click the [Start[Ent]].
5-10-1. Zoom Brush Position Adjustment
1. Preparations
1) Remove parts indicated in Fig. 5-10-3 from the lens unit.
1) Remove parts indicated in Fig. 5-10-3 from the lens unit.
Zoom Rubber Ring
Polyester Tape (Black) 10mm
Polyester Tape (Black) 10 mm
Brush cover
Fig.
5-10-3
2) Attach the lens to the equipment. (Refer to 5-7-2. Connection of Finished Inspection JIG II and Startup of Lens Adjustment Program
(ActuatorCheckerSSM) .)
3) Start up the lens adjustment program (ACSSM-S-VerX.XX.exe).
4) Click [Setup] and perform the initial setting. (Refer to 5-7-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM) .)
4) Click [Setup] and perform the initial setting. (Refer to 5-7-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM) .)
Click on the first or last page to see other SAL70200G2 service manuals if exist.